7
Travel profiles
The RolMotion/D+ M-868 drive has two travel profiles: stan
-
dard mode and quiet mode.
Standard mode
Quiet mode
Travels at high speed
except before the end
positions. The roller shutter
slats are lowered slowly.
Travel the full path at a
reduced speed
Activation in down direction
of travel:
•
Briefly press the [
DOWN/
CLOSE
▼]
button:
Trav-
el to lower end position.
When placing the blind
slats onto the end
position, the speed is
reduced.
Activation in down direction
of travel:
• Press the [
DOWN/
CLOSE
▼]
button for
about 3 seconds:
Travel
at reduced speed to
lower end position.
• Double click the [
DOWN/
CLOSE
▼] button: The
blind travels to the saved
intermediate position (if
this is not defined, travel
to the lower end position).
Activation in up direction of
travel:
•
Briefly press the [
UP
▲]
button:
Travel to upper
end position.
Activation in up direction of
travel:
• Press the [
UP
▲] button
for
approx. 3 seconds:
Travel at reduced speed
to the upper end position
• Double click the [
UP
▲]
button: The blind travels
to the saved ventilation
position (if this is not de-
fined, travel to the upper
end position).
Change to the quiet mode
travel profile:
•
Press the travel button
for approx. 3 seconds in
the same direction as the
current direction of travel.
Change to the standard
mode travel profile:
•
Press the travel button
briefly
in the same
direction as the current
direction of travel.
The drive responds to the
timer functions of pro-
grammed controllers (Tem-
poTel 2, AstroTec, MultiTec
Touch, Centero Home).
The drive responds to com-
mands from programmed
sensors:
•
Sun sensor: Travel to
intermediate position or
lower end position.
8
Troubleshooting
Problem / Error Possible cause Remedial
action
• The drive does
not start up
• No power
supply
• Drive
overheated
• Check connec-
tion and elec-
trical voltage
• Allow drive to
cool down
• Drive runs only
in one direction
• Faulty
connection
• Error when
programming
the end
positions
• Check
connection
• Re-program
the end
positions
Problem / Error Possible cause Remedial
action
• Drive stops
during travel
• End positions
incorrectly
programmed
• Travel to
intermediate
position
• Re-program
the end posi-
tions
• Drive stops
during travel
and then goes
in the opposite
direction
•
Blind difficult to
move
• Obstacle in
drive path
• Check the
smooth
running of the
blind
• Re-program
the end
positions
• Drive only runs
in standard
mode
• End positions
are not yet
programmed
• Perform at
least two
complete
movements
in the up and
down direction
without
interruption
Fig. 8 Troubleshooting the RolMotion/D+ M-868
9
Servicing
The RolMotion/D+ M-868 is maintenance-free.
10 Service/manufacturer's address
If malfunctions occur or the device is damaged despite
correct handling, contact your contractor.
elero
GmbH
Antriebstechnik
Maybachstr. 30
73278 Schlierbach
Deutschland / Germany
Fon:
+49 7021 9539-0
Fax:
+49 7021 9539-212
www.elero.com
Please visit our website if you require a contact partner
outside Germany.
11 Repairs
Please contact your specialist if you have any questions.
Please always provide the following information:
• Item number and designation on the type plate
• Type of fault
• Accompanying conditions
• Your own theories regarding the cause of the problem
12 Disassembly and disposal
After unpacking, dispose of the packaging in accordance
with the valid regulations.
Dispose of the product in accordance with the relevant
regulations when you no longer need it. Disposal is partially
subject to applicable legal regulations. Bring the product to
be disposed of to authorised collection points only.
Environmental information
No superfluous packaging materials have been used. The
packaging can be easily separated into three material
types: cardboard (box), polystyrene (padding) and polyeth-
ylene (bag, protective foam).
©
elero
GmbH
EN | 7
End position settings