elero RolMotion/D+ M-868 Operating And Assembly Instructions Manual Download Page 6

Programming additional transmitters 

Operating procedure 

Result 

3

On the 

(additional) trans-

mitter to be programmed,

 

press the [

UP 

▲] button im

-

mediately (within 1 second) 

after the blind starts moving 

upwards.

The status display 

lights briefly. The blind 

stops briefly, starts 

moving again and then 

moves downwards. 

4

On the (additional) 

transmit-

ter to be programmed, 

press 

the [

DOWN/CLOSE 

▼] 

button immediately (within  

1 second) after the blind 

starts moving downwards. 

The status display 

lights briefly. The drive 

will stop. 

The additional transmitter is programmed. 

Stop the bidirectional radio programming mode:  

Hold down the [

STOP ■

] button for at least 6 seconds until 

the status display lights up (depends on transmitter). 

6.3  Deleting the radio connection between 

transmitters and receivers 

Refer to the respective instructions for the transmitter. 

6.4  Programming or deleting further blind 

positions 

•  Intermediate position: Blind at any position between 

upper and lower end position. 

Defining the 

interim position 

in the receiver 

Approaching 

the intermedi-

ate position 

Deleting the 

intermediate 

position 

Prerequisite: The blind 

is in the upper end 

position. 

1. Press the [

DOWN/

CLOSE 

▼] button 

until the required 

intermediate position 

is reached. 

2. Then press the 

[

STOP 

] button

. The 

blind will stop. The 

status LED lights up 

briefly. 

The intermediate posi-

tion is now stored. 

Prerequisite: The 

intermediate position is 

defined. 

•  Double click the 

[

DOWN/CLOSE 

▼] 

button 

(twice in quick 

succession):  

Blind moves to the 

saved intermediate 

position. 

If no intermediate posi-

tion has been defined, 

the blind moves to the 

lower end position. 

If an intermediate 

position is to be 

controlled for several 

receivers simultane-

ously, the receivers 

must be programmed 

on one channel (single 

channel). 

•  Simultaneously press 

and hold the [

DOWN/

CLOSE 

▼] + 

[

STOP 

■] 

buttons for 

approx. 3 seconds. 

The intermediate 

position is now deleted. 

The status LED lights 

up briefly. 

•  Ventilation position:  

Ventilation gaps for application of the roller shutters open 

Defining the 

ventilation 

position in the 

receiver 

Approaching 

the ventilation 

position 

Deleting the 

ventilation 

position 

Requirement:  

Blind is in the lower 

end position. 

1. Press the [

UP 

▲] 

button until the venti-

lation gaps open. 

2. Then press the 

[

STOP 

] button

.  

The blind stops. The 

position of the ventila-

tion is now saved. 

Prequisite:  

Ventilation posi tion is 

defined. 

•  Double click on the 

[

UP 

▲] button: 

 

The blind travels 

upwards to the saved 

position. 

If no ventilation position 

is defined, the blind 

moves to the upper 

end position.  

•  Simultaneously 

press and hold the 

[

UP 

▲]+[

STOP 

buttons for approx 

3 seconds. 

The position of the ven-

tilation is now deleted. 

Approach to the intermediate position and the ventilation posi-

tion takes place in the quiet mode travel profile (see section 7). 

6 | EN  

© 

elero

 GmbH 

Relief function | End position adjustment 

Changing/deleting the end positions 

Switch on mains 

Use the assembly cable to bring the blind to a central 

position. 

Press both direction keys [

UP

 ▲]+[

DOWN/CLOSE 

▼] 

simultaneously. 

The drive travels up and down briefly for approx. 

 

5 seconds. 
The end position settings have been deleted. 

The end positions are configured again automatically as 

described in section 5.4.4. 

Programming the transmitter
Important

Precondition: The drive must be in radio operation mode. 

 

If the end positions have not been programmed, remove 

the blind from the winding shaft. 

6.1 

Programming the first transmitter 

Programming the (first) transmitter 

Operating procedure 

Result 

Switch the power off and 

on again 

The drive is in learning 

mode for approximate-

ly 5 minutes. 

Press the programming but-

ton [

P

] on the transmitter to 

be programmed for approxi-

mately 1 second. 

The status display 

lights up. The drive is 

now in learning mode 

(up/down travel) for 

approximately  

2 minutes. 

Immediately (maximum 1 

second) after the start of 

upward travel, press the 

[

UP 

▲] button. 

The status display 

lights briefly. The blind 

stops briefly, starts 

moving again and then 

moves downwards. 

4

Immediately (maximum 1 

second) after the start of 

downward travel, press the 

[

DOWN/CLOSE 

▼] button. 

The status display 

lights briefly. The drive 

will stop.

The (first) transmitter is now programmed. 

6.2  Programming additional transmitters 

Up to 16 transmitters can be programmed. 

Programming additional transmitters 

Operating procedure 

Result 

On an 

already programmed 

transmitter,

 hold down 

the buttons [

UP 

▲]+ 

[

DOWN/CLOSE 

▼]+[

P

(programming button) 

simultaneously for 

approximately 3 seconds. 

The status display 

lights up.  

The drive is in learning 

mode for approximate-

ly 5 minutes. 

(alternative to the previous 

line)

Switch the power off and 

on again 

The drive is in learning 

mode for approximate-

ly 5 minutes. 

On the 

(additional) trans-

mitter to be programmed,

 

press the programming 

button [

P

]. 

The status display lights 

briefly. The drive is in 

learning mode (up/

down travel) for approx-

imately 2 minutes. 

Summary of Contents for RolMotion/D+ M-868

Page 1: ...idelines The safety of the product is confirmed by the declaration of conformity see EC Declaration of Conformity All in formation relating to safety in these operating instructions refers to the laws...

Page 2: ...th the manufacturer elero GmbH Antriebstechnik see Ad dress The plant operator shall be solely responsible for any dam ages arising from the improper use of this product The manufacturer cannot be hel...

Page 3: ...addition to the usual travel profile standard mode travel profile the RolMotion D M 868 drive also has a reduced speed travel profile quiet mode travel profile Slow travel when placing the roller shut...

Page 4: ...nical fastening Electrical connection Selection of motor bearing by torque specifications The drive must be protected with all the enclosed safety devices Check for correct engagement on motor bearing...

Page 5: ...UDO FRQGXFWRU ODFN 5HG UHHQ Fig 6 Connection for assembly cable Switch on mains You can now set the end positions with the elero assembly cable 5 4 2 Radio connection transmitter operation ODX 1HXWUDO...

Page 6: ...tilation posi tion is defined Double click on the UP button The blind travels upwards to the saved position If no ventilation position is defined the blind moves to the upper end position Simultaneous...

Page 7: ...drive to cool down Drive runs only in one direction Faulty connection Error when programming the end positions Check connection Re program the end positions Problem Error Possible cause Remedial acti...

Page 8: ...s and regula tions prevailing at the time of scrapping the product must be observed Ensure that materials and components are recycled dis mantled and separated properly in addition to observing the en...

Page 9: ...P Code 44 44 44 44 Limit switch range revolutions 70 70 70 70 Operating time min S2 10 10 10 10 Radio frequency band MHz 868 0 to 868 60 869 4 to 869 65 Radio transmission power dBm Max 10 Max 10 Max...

Page 10: ...E E 45 O 55 C D 33 33 C D 33 E 45 O 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 E E C D 33 33 C D 33 E 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 C D...

Page 11: ...elero GmbH EN 11 Technical data and dimensions...

Page 12: ...We reserve the right to make technical changes elero GmbH Antriebstechnik Maybachstr 30 73278 Schlierbach Germany info elero de www elero com...