elero RolMotion/D+ M-868 Operating And Assembly Instructions Manual Download Page 5

Damage to the blind due to incorrect travel direction. 

 

The assignment of the UP/DOWN direction of rotation 

with an elero radio transmitter must be checked after the 

programming process. 

Connect only in de-energised state. To do this, switch 

the drive cable so it is de-energised.

 

1  

Press locking mechanism on the motor cable plug to-

wards the cable using a suitable screwdriver. 

2  

Pull out the plug. 

3  

Insert the motor cable plug until the lock engages. 

Removing and inserting the motor cable plug 

Delivery 

condition 

Removing plug 

Inserting plug 

Fig. 4  Removing and inserting the motor cable plug 

5.3  Connection example for RolMotion/D+ M-868 

230 V/50 Hz 

(3) 

(2) 

(1) 

Fig. 5    Connection diagram for RolMotion/D+ M-868 

230 V/50 Hz and cable assignment when using 

Hirschmann plug connection STAS-3 (with bridge) 

Important 

The motor controls in the Open and Down/Closed travel 

directions must be locked against each other. 
A switching time of at least 0.5 seconds must be observed. 

5.4  Commissioning 

Important 

The drive is in commissioning mode when delivered. 

 

The end positions must be adjusted using the 

elero

 

assembly cable (see Fig. 6) or an 

elero

 wall or hand-held 

transmitter (see Fig. 7).  

 

The assembly cable may only be connected to commis-

sion the drive and for adjustment operations 

1

2

3

5.4.1  Connection for assembly cable 

%ODX1HXWUDOOHLWHU

6FKZDU]

%UDXQ

*UQJHOE

HOHUR

HOHUR

:KLWHQHXWUDOFRQGXFWRU

%ODFN

5HG

*UHHQ

Fig. 6  Connection for assembly cable 

 

Switch on mains. 

 

You can now set the end positions with the 

elero

 

assembly cable. 

5.4.2  Radio connection (transmitter operation) 

%ODX1HXWUDOOHLWHU

6FKZDU]

%UDXQ

*UQJHOE

HOHUR

HOHUR

:KLWHQHXWUDOFRQGXFWRU

%ODFN

5HG

*UHHQ

Fig. 7  Radio connection (transmitter operation) 

 

Connect cable wires “UP” 

and

 “DOWN/CLOSE” together 

to phase L (outer conductor). 

 

Switch on mains. The drive buzzes and travels upwards 

and downwards for a short time. 

The drive is in radio mode. 

Teaching or deleting the transmitter, fixing or deleting the 

blind positions: see instructions for the corresponding hand-

held transmitter. 

5.4.3  Operation in non-radio mode 

Important 

If the drive is to be operated in non-radio mode, follow  

the instructions for the RolMotion/D+ M (item  

no. 138251201). 

5.4.4 

Automatic configuration of end positions 

Important

 

To use travel profiles, the upper and lower end positions 

must first be set. 

Automatic teaching of end positions 

1  Connect the electric power in accordance with 

section 5.2. 

2  Check for functioning: If necessary, change or swap 

the assignment of the direction buttons for the operat-

ing switch/push button. 

The drive switches off automatically when the (upper or 

lower) limit stop is reached. 
The teaching process is completed due to subsequent 

travel of the shutter. 

5.4.5  Changing/deleting the end positions 

It is not possible to change or delete individual end posi-

tions. This is always done in pairs (upper and lower end 

position simultaneously). 

 © 

elero

 GmbH

  

EN | 5

Assembly | Electrical connection | Relief function 

Summary of Contents for RolMotion/D+ M-868

Page 1: ...idelines The safety of the product is confirmed by the declaration of conformity see EC Declaration of Conformity All in formation relating to safety in these operating instructions refers to the laws...

Page 2: ...th the manufacturer elero GmbH Antriebstechnik see Ad dress The plant operator shall be solely responsible for any dam ages arising from the improper use of this product The manufacturer cannot be hel...

Page 3: ...addition to the usual travel profile standard mode travel profile the RolMotion D M 868 drive also has a reduced speed travel profile quiet mode travel profile Slow travel when placing the roller shut...

Page 4: ...nical fastening Electrical connection Selection of motor bearing by torque specifications The drive must be protected with all the enclosed safety devices Check for correct engagement on motor bearing...

Page 5: ...UDO FRQGXFWRU ODFN 5HG UHHQ Fig 6 Connection for assembly cable Switch on mains You can now set the end positions with the elero assembly cable 5 4 2 Radio connection transmitter operation ODX 1HXWUDO...

Page 6: ...tilation posi tion is defined Double click on the UP button The blind travels upwards to the saved position If no ventilation position is defined the blind moves to the upper end position Simultaneous...

Page 7: ...drive to cool down Drive runs only in one direction Faulty connection Error when programming the end positions Check connection Re program the end positions Problem Error Possible cause Remedial acti...

Page 8: ...s and regula tions prevailing at the time of scrapping the product must be observed Ensure that materials and components are recycled dis mantled and separated properly in addition to observing the en...

Page 9: ...P Code 44 44 44 44 Limit switch range revolutions 70 70 70 70 Operating time min S2 10 10 10 10 Radio frequency band MHz 868 0 to 868 60 869 4 to 869 65 Radio transmission power dBm Max 10 Max 10 Max...

Page 10: ...E E 45 O 55 C D 33 33 C D 33 E 45 O 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 E E C D 33 33 C D 33 E 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 C D...

Page 11: ...elero GmbH EN 11 Technical data and dimensions...

Page 12: ...We reserve the right to make technical changes elero GmbH Antriebstechnik Maybachstr 30 73278 Schlierbach Germany info elero de www elero com...

Reviews: