18
Assembly
4.3
Electrical connection variants
Variants 230 V AC
Variants 24 V DC
WS 9902
GS 9805
WS 9905
GS 9806
Tab. 2 Electrical connection variants
4.3.1
Electrical connection for variants with 230 V 1 AC
WARNING
Risk of life-threatening injury caused by faulty electrical connection.
Electric shock possible.
•
Check the proper connection of the PE cable before the initial commissio-
ning.
CAUTION
Damage to the device through faulty electrical connection.
•
Do not connect connection N to 230 V/50 Hz.
•
Avoid simultaneous application of voltage to conductors „R“ and „V“.
CAUTION
Damage to the device through overload of the potential-free outputs.
•
The potential-free outputs for the response of the end positions can only be
operated with maximum 24 V DC/1 A ohmic load.
Valid signals for response only arise after applying the operating voltage.
Drive position
Signal of response outputs
Device switched off
Both closed "1"
Device retracts or extends
Both open "0"
Device moves to retracted end
position
Retracted, closed "1",
extended, open "0"
Device moves to extended end
position
Retracted, open "0",
extended, closed "1"
Tab. 3 Function of the response contacts