background image

Symbol Signal 

word

Meaning

ATTEN-

TION

This symbol warns 

against possible damage 

to property or equipment.

IMPORT-

ANT 

This symbol indicates 

important facts and states 

as well as referring to fur-

ther information in these 

operating and assembly 

instructions. It also refers 

to certain additional in-

structions, which provide 

additional information or 

help you to carry out a 

procedure more simply.

 

Protection class I symbol 

Fig. 3  Notation for damage to property and additional 

information 

The following example illustrates the basic structure of a safety 

note: 

SIGNAL WORD

Type and source of danger 
Explanation of type and source of danger 

 

Measures to avoid the danger 

Product description 

The InDrive M30/1.6 RH is an electromechanical tubular drive 

for sun protection systems with horizontally moving slats. 

During operation it executes radial movements. 

 

‰

Commissioning of the InDrive M30/1,6 RH with 

elero

 

assembly cable for the configuration of various functions. 

 

‰

Slat protection with free travel (torque limiting). 

 

‰

Release function for the slats 

4.1  Product contents 

Drive with safety instructions and operating instructions and 

any additional components and accessories according to the 

order confirmation or delivery note.

 

4.2  Accessories 

Connection and assembly cable, adapter sets, motor bearing, 

ProLine control units, sensors, receivers. 

Assembly 

WARNING 

Important safety instructions. 
Observe all assembly instructions since incorrect assembly 

can lead to serious injuries. 

 

Commissioning of the InDrive M30/1.6 RH with elero 

assembly cable for setting various functions. 

 

Before installation, all cables and components that are not 

required and all facilities that are not needed for operation 

with a power drive are to be disabled. 

 

►The required components are: drive, connection and 

assembly cable, motor bearing, adapter sets, if necessary 

rigid shaft connectors, sensors, control devices, receivers. 

 

If components are not delivered with the drive, these can 

be identified via our catalogue "Drives and control units for 

intelligent building technology" in the relevant valid version. 

Further details can be found on our website under "Contact 

- Dealer Search" and "Contact - Partner Area". 

 

►The rated torque and rated operating time must be suitable 

for the properties of the driven part (the slats of the sun 

roof). 

 

The coupling of the drive with the powered part is described 

in the section "Mechanical fastening". 

CAUTION 

Risk of injuries due to hot surfaces. 
The drive will heat up during operation, the drive casing can 

become hot. Skin burns are possible. 

 

►Wear personal protection equipment (protective gloves). 

Triggered by a possible material fault, knocks or impact 

injuries may arise due to a gear fracture, burring fracture or a 

coupling defect. 

 

Suitable materials have been used for the engineering 

design and random sample testing by means of a double 

load test has been performed in accordance with DIN EN 

60335-2-97. 

Risk of injury due to knocks or impact triggered by motor 

bearings that are incorrectly mounted or engaged. Hazard 

due to insufficient stability or steadiness and accumulated 

energy (gravity). 

 

►Selection of motor bearing by torque specifications. 

 

The drive must be protected with all the enclosed safety 

devices. 

 

Check for correct engagement on motor bearing and the 

correct screw tightening torques. 

WARNING 

Risk of injury due to electric current. 
Risk of electric shock. 

 

Always have electrical work carried out by an authorised 

electrician. 

Risk of injury due to electric current. 
Possible danger due to parts that are faulty becoming 

energised. 

 

Electrical connection is described in the operating and 

assembly instructions, including cable routing. 

 

The drive falls under protection class I (protective 

conductor system). All housing parts of the drive capable 

of conducting electricity are connected with the protective 

conductor system of the fixed electrical installation, which 

is located at potential earth. The protective conductor 

connection is designed so that, the first time the plug is 

inserted, it is connected first and, in case of any damage, 

it is disconnected last. The connecting cable is fitted with 

mechanical strain-relief when inserted in the drive. If the 

cable is torn out, the protective conductor will be torn off last. 

If, in case of a fault, a live cable comes into contact with the 

housing, which is connected with the protective conductor, 

a short circuit will generally arise so that the fuse itself is 

triggered and de-energizes the electric circuit. No electricity 

will be conducted to human beings in case of a fault. 4-core 

connecting cables (4 x 0.75 mm

2

 cross-section with black 

CONINVERS

 plug) are used for the electrical connection with 

an earthing contact that is conducted to the exterior. 

CAUTION 

Risk of injury due to malfunctions as a result of incorrect 

assembly. 

 © 

elero

 GmbH

  

EN | 3

Product description | Assembly (mechanical fastening) 

Summary of Contents for InDrive M30/1.6 RH

Page 1: ...Declaration of Conformity All information relating to safety in these operating instructions refers to the laws and regulations that are currently valid in Germany All information in these operating instructions must be complied with at all times and without limitation In addition to the safety notes in these operating instructions the regulations on accident prevention environmental protection an...

Page 2: ...urer elero GmbH Antriebstechnik see Address The plant operator shall be solely responsible for any damages arising from the improper use of this product The manufacturer cannot be held liable for personal or material damages caused by misuse or procedural errors nor by improper operation or commissioning The product may only be operated by instructed and authorised specialist personnel while obser...

Page 3: ...ith the powered part is described in the section Mechanical fastening CAUTION Risk of injuries due to hot surfaces The drive will heat up during operation the drive casing can become hot Skin burns are possible Wear personal protection equipment protective gloves Triggered by a possible material fault knocks or impact injuries may arise due to a gear fracture burring fracture or a coupling defect ...

Page 4: ...ts of the application For safe operation the end positions must be set taught in Manufacturer training is available for specialist companies ATTENTION Power failures breaking of machine parts and other malfunctions For safe operation assembly must be correct and the end positions must be configured upon commissioning Damage to InDrive M30 1 6 RH due to the penetration of moisture On devices with p...

Page 5: ... end positions If an end position was taught in at a limit stop a release can also be enabled for the slats Important The release function for variants B to D is activated in a single step when programming the end positions see chapters 5 6 7 to 5 6 9 5 6 2 Release function in initial position For variant B see chapter 5 6 7 and variant C see chapter 5 6 8 Activate release function in initial posi...

Page 6: ...riant C 6 EN elero GmbH Setting the end positions and release 5 6 5 Four end position variants Four different end position settings are possible These can be selected as appropriate according to the technical requirements of the slats End positions 4 variants A Initial position and end position freely adjustable B Initial position at limit stop end position freely ad justable C Initial position an...

Page 7: ...sible cause Remedial action End positions cannot be taught into the drive Random travel Travel to end position or limit stop too short Delete end positions re programme end positions Drive must move stop briefly and continue its travel as long as a button on the assem bly cable is pressed Fig 11 Troubleshooting for the InDrive M30 1 6 RH 7 Servicing The InDrive M30 1 6 RH requires no maintenance 8...

Page 8: ...nies Groups of materials such as various types of plastics and metals must be separated before recycling disposal Disposal of electrical and electronic components The disposal and recycling of electrical and electronic components must be carried out in accordance with the relevant laws and national regulations 11 Conformity Declaration elero GmbH hereby declares that this product conforms with the...

Reviews: