IMPORTANT SAFETY INFORMATION
(Continued)
• Before each use, remove the lava rocks. Examine the burner and its components. If dirty, clean with a
soft brush and soapy water solution. Also examine the area around the burner. Any dirt or foreign
material, such as spider webs or nests in this area should be removed. If it is evident that the burner is
damaged, the fire table must not be used. The burner assembly cannot be replaced. Please contact
Elementi at 909-985-553 for technical support.
• Place the hose out of the pathways where people may trip over it. Do not place the hose in areas where it
may be subjected to accidental damage.
ATTENTION
:
Any alteration of the outdoor fire table that is not specifically directed in the
operations manual will void manufacturer warranty.
NATURAL GAS DANGERS AND WARNINGS
Natural gas is flammable and hazardous if handled improperly. Become aware of the
characteristics before using any natural gas product.
Natural Gas Characteristics:
• Flammable, explosive under pressure, lighter than air and settles in pools in high areas.
• In its natural state, natural gas has no odor. For your safety,an odorant has been added.
• Contact with natural gas could burn the skin.
• Natural gas is extremely flammable and hazardous if handled improperly.
Chemicals known to the state of California to cause cancer, birth defects, or other
reproductive harm are created by the combustion of natural gas.
Your natural gas fire pit is designed to operate on natural gas only, at a pressure of seven
inches’ water column (7" W.C.) Check with your gas utility for local gas pressure, because in
some areas natural gas pressure varies. Also, check with your gas company or with local
building codes for instructions to install gas supply line, or call a licensed and qualified
installer.
It is recommended that an ON/OFF manual shut-off valve be installed at the gas supply
source:
Outdoors after the gas line exits outside wall and before quick-disconnect or
before gas supply line enters ground.
Indoors in the branch gas line in an accessible location near the gas supply line.
Pipe sealing compound or pipe thread tape of the type resistant to the action of natural
gas must be used on all male pipe threads. Apply compound or tape to at least the first
three to four threads when making a connection.
!
DANGER
This outdoor fire table is for use with natural gas only. The conversion to or attempted use of
Liquid Propane in this out door fire table is dangerous and could result in serious personal
injury, or property damage.