PRE-USE INSTRUCTIONS

Prior to each gas fire table operation, check the hose and

valve for evidence of excessive abrasion or wear

through the visual check hole on the side of the base.

Replace visual check cap prior to operating fire table.

Burner Connections

Make sure the Natural Gas hose and quick disconnect

socket connections are securely fastened to the burner

and the gas supply. If your unit was assembled for you,

visually check the connection between the burner pipe

and orifice. Make sure the burner pipe fits over the orifice.

Please refer to diagram for proper installation.

If the burner pipe does not rest flush to the orifice, please

contact Elementi at 1-900-985-5553 for assistance.

Checking for Leaks

Make a leak check solution by mixing 1-part dishwashing soap with 3

parts water in a spray bottle.

Make sure control knob is “OFF.” Then, turn natural gas on at its

source.

Spray leak solution on valve connections paying particular attention to

the areas indicated by arrows.

If any bubbles appear turn natural gas off, reconnect and

re-test. If you continue to see bubbles after several attempts,

disconnect natural gas source and contact Elementi at 1-909-985-

5553 for assistance.

If no bubbles appear after one-minute turn source

OFF, wipe away solution and proceed.

6

WARNING

Before using this outdoor fire table, make sure

you have read, understand and are

following all information provided in the Important Safety Information section of this

manual. Failure to follow those instructions can cause death, serious injury or property

damage.

WARNING

Failure to inspect this connection or follow these instructions could cause a fire

or an explosion, which can cause death, serious bodily injury, or damage to

property.

Check for leaks at these locations

Summary of Contents for OFE102-NP

Page 1: ...ly with Natural gas WARNING If the information in this manual is not follow exactly a re or explosion may result causing property damage personal injury or loss of life Read the installation operation...

Page 2: ...2 Care and Cleaning 13 Gas Component Connection Checks 14 Troubleshooting 16 Warranty 18 Table of Contents DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Us...

Page 3: ...se this outdoor re table on a hard level non combustible surface such a concrete rock or stone An asphalt or blacktop surface may not be acceptable for this purpose Surfaces such as dirt and grass may...

Page 4: ...been under water DO NOT wear flammable or loose clothing when operating this outdoor re table DO NOT use in windy conditions Keep all electrical cords away from a hot outdoor fire table Certain areas...

Page 5: ...h natural gas could burn the skin Natural gas is extremely ammable and hazardous if handled improperly Chemicals known to the state of California to cause cancer birth defects or other reproductive ha...

Page 6: ...se to manual shut off valve at the gas supply The outdoor re table must be isolated from the gas supply piping system by closing the Individual manual shut off valve during any pressure testing of the...

Page 7: ...7 18 PARTS LIST Fire Table 1 Natural Gas Hose 1 and Quick Disconnect Lava Rock 1 1 2 3 3 1 2...

Page 8: ...ded Place lava rock by hand DO NOT dump bag out in to the tray to avoid clogging the burner with dust Position the lava rock 10kgs to a level about 1 above the t op of the burner Make sure that you do...

Page 9: ...connection must be made outdoors Connecting the Socket Coat the gas supply pipe nipple with gas resistant pipe compound or approved Teflon PTFE tape Screw socket onto gas supply pipe house gas source...

Page 10: ...ct socket and insert the unattached end of the gas hose into the socket Release the sleeve and continue pushing the hose into the socket until the sleeve snaps into the locked position After making al...

Page 11: ...with 3 parts water in a spray bottle Make sure control knob is OFF Then turn natural gas on at its source Spray leak solution on valve connections paying particular attention to the areas indicated b...

Page 12: ...does not occur in 30 seconds turn control knob to the OFF position and turn gas off at the source wait 5 minutes until gas has cleared and repeat lightingprocedure 9 After lighting rotate the burner...

Page 13: ...rection of the polish lines 4 Note Even the finest cleaning powders can scratch or burnish a mill rolled finish On polished finishes rubbing or wiping should be done in the direction of polish lines 1...

Page 14: ...e sure the electrode wire is correctly connected Both elect rode wires must be fully inserted in to the igniter box 2 Make sure that the pilot housing is unobstructed Clear any debris on top of the pi...

Page 15: ...pointed straight to the thermocouple The thermocouple should be positioned 5mm away from the burnertube Thermocouple Wire Valve 4 Make sure that the thermocouple wire is correctlypositioned The thermo...

Page 16: ...will not light with match Possible Cause 1 No gas flow Check if natural gas supply is stopped If it is not stopped refer to Problem Sudden drop in gas ow on the following page Possible Cause 2 Quick...

Page 17: ...econnect the quick disconnect socket turn on the main gas supply and perform a leak check at the natural gas connection Problem Irregular ame pattern ame does not run the full length of the burner Pos...

Page 18: ...warranty is non transferable and applies only for units that are for non commercial personal use only Under this warranty agreement all gas lines must be installed by a licensed gas fitter Damage caus...

Reviews: