IMPORTANT SAFETY INFORMATION

!

WARNING

FIRE TABLE IS FOR OUTDOOR USE ONLY

WARNING:

Always shut off gas supply at the shut-off valve and disconnect the quick disconnect

socket from the main gas supply when the fire table is not in using.

WARNING:

Installation and service must be performed by a qualified installer, service agency or gas

supplier.

WARNING:

Failure to follow with the safety warnings and precautions in this manual

may result in serious bodily injury or death, a fire or an explosion causing damage to

property.

IMPORTANT NOTICE:

Read and understand all warnings and precautions prior to assembly and

use your gas fire table. Improper installation, adjustment, alteration, service or maintenance can

cause injury or property damage.

NOTE:

The use and installation of this product must conform to local codes. In the absence of

local code s, use the National Fuel Gas Code, ANSI Z21.97. Reference to Natural Gas and Propane

Installation code CSAB14 9.1 or Propane Storage and Handling code B149.2.

NOTE:

When an appliance is for connection to a fixed piping system, the installation must conform with

local codes, or in the absence of local codes with the National Fuel Gas Code, ANSI Z223.1/NFPA 54,

or International Fuel Gas Code.

Minimum clearance from unit to combustible materials 72” (182.9cm) from the top; 48” (121.9 cm) from

all sides and back. Do not locate this fire table under any overhead enclosure.

Always use this outdoor fire table on a hard, level non-combustible surface such a concrete, rock or

stone. An asphalt or blacktop surface may not be acceptable for this purpose. Surfaces such as dirt

and grass may prevent the unit from having proper ventilation.

This gas fire table and its individual shut off valve must be disconnected from the gas supply piping

system during any pressure testing of that system at test pressures in excess of 1/2 of psi

(3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual

manual shut off valve during any pressure testing of the gas supply piping system at test pressures

equal to or less than 1/2 psi (3.5 kPa).

Keep these instructions for future reference. If you are assembling this unit for someone else,

give this manual to him or her to read and keep for f utu re reference.

This gas fi re table must be used ONLY out doors in a well- ventilated space and shall NOT be

used inside a building, garage, or any other enclosed area.

DO NOT use this outdoor gas fi re table for indoor heating. Toxic carbon monoxide fumes can

accumulate and cause asphyxiation.

NEVER leave this gas fire pit unattended when in use.

Children should be alerted to the hazards of high surface temperatures and kept at a safe distance

while fire table is in use.

IF YOU SMELL GAS:

Shut off gas supply to the fire table.

Extinguish any open flame.

Do not try lighting any appliance.

Do not touch any electrical switch, do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If you cannot reach your gas supplier, call the fire department.

Summary of Contents for OFE102-NP

Page 1: ...ly with Natural gas WARNING If the information in this manual is not follow exactly a re or explosion may result causing property damage personal injury or loss of life Read the installation operation...

Page 2: ...2 Care and Cleaning 13 Gas Component Connection Checks 14 Troubleshooting 16 Warranty 18 Table of Contents DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Us...

Page 3: ...se this outdoor re table on a hard level non combustible surface such a concrete rock or stone An asphalt or blacktop surface may not be acceptable for this purpose Surfaces such as dirt and grass may...

Page 4: ...been under water DO NOT wear flammable or loose clothing when operating this outdoor re table DO NOT use in windy conditions Keep all electrical cords away from a hot outdoor fire table Certain areas...

Page 5: ...h natural gas could burn the skin Natural gas is extremely ammable and hazardous if handled improperly Chemicals known to the state of California to cause cancer birth defects or other reproductive ha...

Page 6: ...se to manual shut off valve at the gas supply The outdoor re table must be isolated from the gas supply piping system by closing the Individual manual shut off valve during any pressure testing of the...

Page 7: ...7 18 PARTS LIST Fire Table 1 Natural Gas Hose 1 and Quick Disconnect Lava Rock 1 1 2 3 3 1 2...

Page 8: ...ded Place lava rock by hand DO NOT dump bag out in to the tray to avoid clogging the burner with dust Position the lava rock 10kgs to a level about 1 above the t op of the burner Make sure that you do...

Page 9: ...connection must be made outdoors Connecting the Socket Coat the gas supply pipe nipple with gas resistant pipe compound or approved Teflon PTFE tape Screw socket onto gas supply pipe house gas source...

Page 10: ...ct socket and insert the unattached end of the gas hose into the socket Release the sleeve and continue pushing the hose into the socket until the sleeve snaps into the locked position After making al...

Page 11: ...with 3 parts water in a spray bottle Make sure control knob is OFF Then turn natural gas on at its source Spray leak solution on valve connections paying particular attention to the areas indicated b...

Page 12: ...does not occur in 30 seconds turn control knob to the OFF position and turn gas off at the source wait 5 minutes until gas has cleared and repeat lightingprocedure 9 After lighting rotate the burner...

Page 13: ...rection of the polish lines 4 Note Even the finest cleaning powders can scratch or burnish a mill rolled finish On polished finishes rubbing or wiping should be done in the direction of polish lines 1...

Page 14: ...e sure the electrode wire is correctly connected Both elect rode wires must be fully inserted in to the igniter box 2 Make sure that the pilot housing is unobstructed Clear any debris on top of the pi...

Page 15: ...pointed straight to the thermocouple The thermocouple should be positioned 5mm away from the burnertube Thermocouple Wire Valve 4 Make sure that the thermocouple wire is correctlypositioned The thermo...

Page 16: ...will not light with match Possible Cause 1 No gas flow Check if natural gas supply is stopped If it is not stopped refer to Problem Sudden drop in gas ow on the following page Possible Cause 2 Quick...

Page 17: ...econnect the quick disconnect socket turn on the main gas supply and perform a leak check at the natural gas connection Problem Irregular ame pattern ame does not run the full length of the burner Pos...

Page 18: ...warranty is non transferable and applies only for units that are for non commercial personal use only Under this warranty agreement all gas lines must be installed by a licensed gas fitter Damage caus...