background image

INSTALLATION GUIDE 

|

 DIM-TO-WARM LED TAPE LIGHT 

|

 IG090519-1.0 

|

 3 OF 5

INSTALLATION GUIDE

CELESTE DIM-TO-WARM LINEAR LIGHTING

Prior to mounting, attach to Class 2 magnetic LED Driver, turn on 

power and test connection to ensure system is operating properly. 

Turn off power again before mounting. 

a

b

+

-

+ 24V

-

+

-

Clean surface before mounting.

MOUNT TAPE LIGHT

TURN POWER ON AT CIRCUIT BREAKER

SYSTEM WORKING IMPROPERLY?

Turn power OFF at circuit breaker and verify all connections. 

Review SYSTEM DIAGRAMS and TROUBLESHOOTING or 

call our Technical Support line at 877.817.6028.

Peel off 3M

 Adhesive Backing. 

Ensure ambient 

temp is minimum 50 ° F (10 ° C) or tape will not 

adhere properly.

Tear off backing along connector edge.

Adhere to a smooth, dry surface, working one end to 

the other, being gentle with the LED’s.

INSTALLATION (CONT.)

8.1

8.2

7

TEST CONNECTION

8

9

Summary of Contents for LUCETTA CELESTE

Page 1: ...e installed and serviced by a qualified licensed electrician 3 Do not modify or disassemble this product beyond instructions or the warranty will be void 4 Do not submerge or install within 5 feet of a swimming pool 5 All plastics are affected by the elements and may shift in color and other properties after product installation particularly with direct exposure to sun chlorinated water and other ...

Page 2: ...re applicable wire is installed between driver fixture and any controls in between When choosing wire factor in voltage drop amperage rating and type in wall rated wet location rated etc CUT TAPE LIGHT TO DESIRED LENGTH 24V 24V 24V 24V 24V 24V 24 Cut at line indicated with scissors icon PREPARE CONNECTOR Using Phillips Head Screwdriver fasten connector to Strip Light 2 4 V 2 4 V INSERT TAPE LIGHT ...

Page 3: ... mounting MOUNT TAPE LIGHT TURN POWER ON AT CIRCUIT BREAKER SYSTEM WORKING IMPROPERLY Turn power OFF at circuit breaker and verify all connections Review SYSTEM DIAGRAMS and TROUBLESHOOTING or call our Technical Support line at 877 817 6028 Peel off 3M Adhesive Backing Ensure ambient temp is minimum 50 F 10 C or tape will not adhere properly Tear off backing along connector edge Adhere to a smooth...

Page 4: ...ded overheated driver will trip the internal auto reset of driver repeatedly turning the system on off Wire Gauge 10 W 42 A 20 W 83 A 30 W 1 3 A 40 W 1 7 A 50 W 2 1 A 60 W 2 5 A 70 W 2 9 A 80 W 3 3 A 90W 3 75 A 100 W 4 2 A 20 AWG 85 ft 43 ft 27 ft 21 ft 17 ft 14 ft 12 ft 11 ft 9 ft 8 ft 18 AWG 134 ft 68 ft 45 ft 33 ft 27 ft 22 ft 19 ft 17 ft 15 ft 14 ft 16 AWG 215 ft 109 ft 72 ft 54 ft 43 ft 36 ft...

Page 5: ...ide for detailed and up to date wiring instructions Install in accordance with national and local electrical codes Magnetic Dimmable Driver System 1 Driver may not require a fault ground connection Refer to driver specifications for additional information 2 Install a compatible Class 2 driver Refer to each driver specification sheet for full power ratings load deratings 8 See fixture specification...

Reviews: