INSTALLATION GUIDE 

|

 DIM-TO-WARM LED TAPE LIGHT 

|

 IG090519-1.0 

|

 2 OF 5

INSTALLATION GUIDE

CELESTE DIM-TO-WARM LINEAR LIGHTING

Prior to installation, verify all components (LED Tape, Driver, Control, & 

Accessories) are compatible. Configure and pre-test your LED system prior to 

installation to ensure all components are operating correctly. 

SHOCK HAZARD!

 

May result in serious injury 

or death.

Turn power OFF at circuit breaker prior to 

installation.

+ 24V

-

+

-

+ 24V

-

+

-

+ 24V

-

+

-

+ 24V

-

+

-

1) Class 2 

Magnetic Driver

2) Control

3) Tape Light

Refer to 

SYSTEM DIAGRAMS.

WIRE GAUGE & VOLTAGE DROP

Ensure  applicable  wire  is  installed  between  driver,  fixture, 

and any controls in between. When choosing wire, factor in 

voltage drop, amperage rating, and type (in-wall rated, wet 

location rated, etc.)

CUT TAPE LIGHT TO DESIRED LENGTH

+ 24V

-

+

-

+ 24V

-

+

-

+ 24V

-

+

-

+ 24V

-

+

-

+ 24V

-

+

-

+ 24V

-

+

-

+ 24V

-

+

-

+ 24V

-

+

-

Cut at line indicated with scissors icon. 

PREPARE CONNECTOR

Using Phillips Head Screwdriver, fasten connector to Strip 

Light.

-

24V

-

+

-

+

-

24V

-

+

-

+

INSERT TAPE LIGHT INTO CONNECTOR

UNSCREW TERMINAL BLOCK CONNECTOR

TERMINAL CONNECTOR

SECURE STRIP LIGHT

Never cut tape attached to a live circuit. Do not exceed Class 2 

Limit when loading CELESTE

 Connectors.

Firmly insert with 3M

 Adhesive backing still intact to 

Tape Light.

INSTALLATION

1

TURN POWER OFF AT CIRCUIT BREAKER

2

DETERMINE LOCATION TO INSTALL 

COMPONENTS

3

4

5

6

Summary of Contents for LUCETTA CELESTE

Page 1: ...e installed and serviced by a qualified licensed electrician 3 Do not modify or disassemble this product beyond instructions or the warranty will be void 4 Do not submerge or install within 5 feet of a swimming pool 5 All plastics are affected by the elements and may shift in color and other properties after product installation particularly with direct exposure to sun chlorinated water and other ...

Page 2: ...re applicable wire is installed between driver fixture and any controls in between When choosing wire factor in voltage drop amperage rating and type in wall rated wet location rated etc CUT TAPE LIGHT TO DESIRED LENGTH 24V 24V 24V 24V 24V 24V 24 Cut at line indicated with scissors icon PREPARE CONNECTOR Using Phillips Head Screwdriver fasten connector to Strip Light 2 4 V 2 4 V INSERT TAPE LIGHT ...

Page 3: ... mounting MOUNT TAPE LIGHT TURN POWER ON AT CIRCUIT BREAKER SYSTEM WORKING IMPROPERLY Turn power OFF at circuit breaker and verify all connections Review SYSTEM DIAGRAMS and TROUBLESHOOTING or call our Technical Support line at 877 817 6028 Peel off 3M Adhesive Backing Ensure ambient temp is minimum 50 F 10 C or tape will not adhere properly Tear off backing along connector edge Adhere to a smooth...

Page 4: ...ded overheated driver will trip the internal auto reset of driver repeatedly turning the system on off Wire Gauge 10 W 42 A 20 W 83 A 30 W 1 3 A 40 W 1 7 A 50 W 2 1 A 60 W 2 5 A 70 W 2 9 A 80 W 3 3 A 90W 3 75 A 100 W 4 2 A 20 AWG 85 ft 43 ft 27 ft 21 ft 17 ft 14 ft 12 ft 11 ft 9 ft 8 ft 18 AWG 134 ft 68 ft 45 ft 33 ft 27 ft 22 ft 19 ft 17 ft 15 ft 14 ft 16 AWG 215 ft 109 ft 72 ft 54 ft 43 ft 36 ft...

Page 5: ...ide for detailed and up to date wiring instructions Install in accordance with national and local electrical codes Magnetic Dimmable Driver System 1 Driver may not require a fault ground connection Refer to driver specifications for additional information 2 Install a compatible Class 2 driver Refer to each driver specification sheet for full power ratings load deratings 8 See fixture specification...