DRY LOCATION

97+

HIGH CRI

DIMMABLE

24VDC

GOLD PLATED PCB

SINGLE SDCM

HIGH R9 & RF SKIN

SPEC LOCK

INSTALLATION GUIDE 

|

 DIM-TO-WARM LED TAPE LIGHT 

|

 IG090519-1.0 

|

 1 OF 5

INSTALLATION GUIDE

CELESTE DIM-TO-WARM LINEAR LIGHTING

SAFETY & WARNINGS

DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!

Read all warnings and installation instructions thoroughly.

WARNING

DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!

Read all warnings and installation instructions thoroughly.

WARNING

WARNING!

DO NOT CONNECT DIRECTLY TO LINE 

VOLTAGE POWER!

Read all warnings and installation instructions 

thoroughly.

HANDLE PRODUCT WITH CARE!

DO NOT

 BEND LED STRIP 

LIGHT TO A DIAMETER LESS 

THAN 

4 INCHES

.

4 in.

DO NOT 

BEND LED STRIP LIGHT 

ON A HORIZONTAL PLANE.

DO NOT

 COVER STRIP LIGHT WITH 

ANY MATERIALS.

DO NOT 

FOLD, CREASE, OR 

TWIST LED STRIP LIGHT.

DO NOT 

POWER STRIP 

LIGHT WHILE ATTACHED TO 

SPOOL OR TIGHTLY COILED.

1. Install in accordance with national and local electrical 

code regulations. 

2. This product is intended to be installed and serviced by 

a qualified, licensed electrician.

3. Do not modify or disassemble this product beyond 

instructions or the warranty will be void.

4. 

Do not submerge, or install within 5 feet of a swimming 

pool. 

5. 

All plastics are affected by the elements and may shift 

in color and other properties after product installation, 
particularly  with  direct  exposure  to  sun,  chlorinated 
water, and other chemicals.

6. Only install with a Listed Class 2 DC LED driver. 
7. 

To  avoid  Voltage  Drop,  ensure  wire  gauge  used  with 
LED Strip Light is sufficient. Refer to Voltage Drop Chart.

8. Do not exceed maximum run recommended for Strip 

Light.

9. CELESTE

 LED Strip Light is designed to be cut at 

designated cut points only. Cutting anywhere other than 
the cut points will result in damage to the Strip Light.

10. 

Failure  to  follow  safety  warnings,  and  installation 

instructions will void the warranty for this product.

POWER SUPPLY

CLASS

2

+ 24V

+ 24V

-

-

W

W

W

W

W

W

C

C

C

C

C

C

+ 24V

+ 24V

-

-

W

W

W

W

W

W

C

C

C

C

C

C

+ 24V

+ 24V

-

-

W

W

W

W

W

W

C

C

C

C

C

C

+ 24V

+ 24V

-

-

W

W

W

W

W

W

C

C

C

C

C

C

Summary of Contents for LUCETTA CELESTE

Page 1: ...e installed and serviced by a qualified licensed electrician 3 Do not modify or disassemble this product beyond instructions or the warranty will be void 4 Do not submerge or install within 5 feet of a swimming pool 5 All plastics are affected by the elements and may shift in color and other properties after product installation particularly with direct exposure to sun chlorinated water and other ...

Page 2: ...re applicable wire is installed between driver fixture and any controls in between When choosing wire factor in voltage drop amperage rating and type in wall rated wet location rated etc CUT TAPE LIGHT TO DESIRED LENGTH 24V 24V 24V 24V 24V 24V 24 Cut at line indicated with scissors icon PREPARE CONNECTOR Using Phillips Head Screwdriver fasten connector to Strip Light 2 4 V 2 4 V INSERT TAPE LIGHT ...

Page 3: ... mounting MOUNT TAPE LIGHT TURN POWER ON AT CIRCUIT BREAKER SYSTEM WORKING IMPROPERLY Turn power OFF at circuit breaker and verify all connections Review SYSTEM DIAGRAMS and TROUBLESHOOTING or call our Technical Support line at 877 817 6028 Peel off 3M Adhesive Backing Ensure ambient temp is minimum 50 F 10 C or tape will not adhere properly Tear off backing along connector edge Adhere to a smooth...

Page 4: ...ded overheated driver will trip the internal auto reset of driver repeatedly turning the system on off Wire Gauge 10 W 42 A 20 W 83 A 30 W 1 3 A 40 W 1 7 A 50 W 2 1 A 60 W 2 5 A 70 W 2 9 A 80 W 3 3 A 90W 3 75 A 100 W 4 2 A 20 AWG 85 ft 43 ft 27 ft 21 ft 17 ft 14 ft 12 ft 11 ft 9 ft 8 ft 18 AWG 134 ft 68 ft 45 ft 33 ft 27 ft 22 ft 19 ft 17 ft 15 ft 14 ft 16 AWG 215 ft 109 ft 72 ft 54 ft 43 ft 36 ft...

Page 5: ...ide for detailed and up to date wiring instructions Install in accordance with national and local electrical codes Magnetic Dimmable Driver System 1 Driver may not require a fault ground connection Refer to driver specifications for additional information 2 Install a compatible Class 2 driver Refer to each driver specification sheet for full power ratings load deratings 8 See fixture specification...