20
APPENDICES
20
A First aid for malfunction
Below you will find an overview of the possible cause and
solution in the event of a failure.
Problem
Possible Cause
Solution
A No transmission
(motor will not
run)
1 Batteries in the receiver empty
Replace the batteries (4x 1.5V AA)
2 Batteries hand remote empty
Replace the batteries (2x 1.5V AAA)
3 6V-adapter defective
Check the adapter
Replace the adapter if necessary
4 Hand transmitter not linked to the receiver
Connect the hand transmitter to the receiver
Press and hold the reset button until you hear two beeps. After
the second longer tone, release the reset button. Press within
20 sec. on the down arrow on the hand transmitter
Two short beeps confirm that the code has been set.
Tip: For this action a video is available on our youtube
channel
B Receiver does not
receive a signal
1 Receiver defective
Replace receiver
2 Bend pin connection on the receiver
Bend the pen straight again (See Figure A-1)
3 Hand transmitter defective
Replace the hand transmitter
4 No or bad reception. The receiver is in a metal
box! This disturbs the reception.
Change the position of the antenna (See Figure A-2)
C No ignition;
no beep
1 Receiver defective
Reset the receiver (See K1)
If necessary, replace the receiver
D No ignition;
receiver gives a
five-second beep
1 Loose contact in the thermocouple circuit / wiring
2nd thermocouple
Check plug connections
Repair the wiring if necessary
2 Receiver defective
Replace receiver
3 Magnetic coil defective
Replace gas block / or only coil coil
4 Bent pin connection on the receiver
See B2
5 Thermocouple broken
Check the thermocouple at the bottom of the pilot burner if
necessary. fracture.
Replace the thermocouple if necessary
E
Ignition stops after
1 spark
1 Mass on the gas block not OK
•
Remove the 20mm Torx screw (See Figure A-3)
•
File or scrape the surface thoroughly
•
Reinstall the Screw and tighten it securely
Tip: For this action a video is available on our youtube
channel
F
No pilot flame but
there is an ignition
1 No gas
Check / measure gas inlet pressure
2 Air in the gas line
Venting the gas line can be done via test point A (See Figure A-4
Tip: For this action a video is available on our youtube
channel
3 Pilot flame blocked
Check pilot burner
4 Thermocouple wiring is incorrect
Check the wiring on the interrupter (See Fig. A-5)
Check the wiring on the receiver (See Fig. A-6)