17
CLEARANCES
Element4 Gas Fireplaces Rev# 03242020
European
Home
.com
A
A
B
B
VENT OPENING
800cm² (124In²)
TOTAL MINIMUM
(2") 50
C
SECTION A-A
(36") 900
(36")
900
(36")
900
SECTION B-B
COMBUSTIBLE MATERIALS
NOT PERMITTED IN FRONT
OF GLASS
(2") 50
(11") 280
DETAIL C
SCALE 1 : 10
CONSTRUCTION
BEAMS NON-
COMBUSTIBLE
(TYPICAL)
TOP OF FIREPLACE
OPENING
GLASS
NON COMBUSTIBLE
MATERIAL
DETAIL C
CONVECTION GAP
CONSTRUCTION
BEAMS COMBUSTIBLE
(TYPICAL)
1”/25 mm
12”/300 mm
13”/330 mm
2”/50 mm
INCHES
M
an
tel Heigh
t
Mantel Depth
MANTELS
The graph below (Figure __) shows a range of allowable depths and heights for a
COMBUSTIBLE
mantel installation.
As shown, the minimum allowable mantel height above the fireplace opening is 2” (50
mm)
with a 1” (25
mm)
deep mantel.
The maximum mantel depth is 12” (300)
mm
at a minimum height above the fireplace opening of 13” (330
mm
.)
All of the mantel height/depth combinations fall in between these extremes in accordance with the chart below.
Mantels made of
non-combustible
material are allowed inside these dimensions but they will be subjected to elevated
temperatures and may become too hot to touch.
A typical completed installation with mantel is shown in the diagram below, on the right.
Figure 16
Figure 17
16