Chapter 5 

I N S T A L L A T I O N   M A N U A L   |

INSTALLATION  PREPARATION AND - INSTRUCTION

The device is developed, tested and approved conform the applicable 
standards  for  the  usage,  the  performance  and  safety    of  the  product. 

The installation of your device must apply to the current building 

prescriptions.    We  advise  to  make  use  of  a  qualified  gas  installer  for 

the installation of your device. The installer can provide you with all 
information regarding the safety regulations of the installation. 

5�1 

RELEVANT NORMS AND GUIDELINES 

The installation must be carried out in accordance with the following 
regulations 

• 

Department of the Environment, the Building Standards (Scotland) 

(Consolidation) Regulations issued by the Scottish Development 
Department.

• 

BS 5440 part 1

• 

BS 5871 part 2

• 

BS 6891.

In the Republic of Ireland the installation must also conform to the 

relevant standards, particularly in regard to flue sizing and ventilation. 
Refer to documents;

• 

 IS813 

• 

ICP3

• 

IS327

• 

Any other rules in force. 

This appliance must be installed in accordance with the rules in force 

and used only in a sufficiently ventilated space, and is intended for use 

on a gas installation with a governed meter.

5�2 

ATTENTION POINTS GAS FIREPLACE

This appliance is a Balanced Flue room sealed appliance, and as such 
needs  no  additional  ventilation.  However  an  adequate  supply  of 

fresh air to maintain temperatures and a comfortable environment is 
recommended. This appliance may be installed in a completely sealed 
or mechanically ventilated house.

5�3 

APPLIANCE INSTALLATION

• 

Determine the position required for the appliance.

• 

Create a gas connection for the appliance in approximately the 
correct location for the gas controls.

• 

The gas controls are connected to the burner of the appliance.

• 

This appliance must be securely fixed to the floor using the fixings 

built into the base of the appliance.

• 

Do not make any adjustments to the appliance.

5�4 

ATTENTION POINTS GAS CONNECTION

The gas connection should apply to the local norms in force. Calculate 

the diamater of the gas flue, such that no pressure loss is occuring in the 
pipes. Place a shut-off valve in the near vicinity of the device.  Position 
the gas connection, such that it is always  accessible for service purposes. 

The gas block and receiver are under the combustion chamber, in the 
deivce, so that it is always  accessible for service purposes. 

5�5 

REQUIREMENTS FLUE AND WALL TERMINALS 

The European CE-marking for the device is only applicable to the flue 
materials specified by the supplier. The device must be installed with 
the stainless steel flue material US by Metaloterm/On top. The usage of 

other concentric stainless steel material is only permitted when it has 

the  same  technical  specification  as  the  previous  mentioned  systems. 

Only when these materials are used a good and safe performance can 
be promised by Element4. 

This appliance may be installed with a roof terminal (C31) or a wall 
terminal (C11). 

This appliance may only be used with Balanced Flue (otherwise known as 
Concentric Flue) parts as specified by Element4. The Element4 specified 
flue  parts  have  been  approved  with  the  appliance.  If  the  appliance  is 
installed on non-Element4 approved parts, Element4 cannot guarantee 

or accept and responsibility for the proper and safe working of the 
appliance.

The flue system must be constructed from the appliance upwards, with 
all  joints  being  fully  locked  and  sealed  using  the  Element4  specified 

parts.

5�6 

BASEMENTS, LIGHT WELLS AND RETAINING WALLS

Flue  terminals  should  not  be  sited  within  the  confines  of  a  basement 
area, light well or external space formed by a retaining wall, unless steps 

are taken to ensure the products of combustion can disperse safely at all 

times. It may be possible to install this Balanced Flue system in such a 

location provided that it is not sited lower than 1m from the top level of 
that area to allow combustion products to disperse safely.

Flue  terminals  should  be  sited  to  ensure  total  clearance  of  the 

combustion products in accordance with the included information.

When  the  products  of  combustion  are  discharged,  they  should  not 

cause a nuisance to adjoining or adjacent properties and they should be 
positioned so that damage cannot occur to other parts of the building. 

If the outer wall surface is constructed of combustible material, a non-
combustible plate should be fitted behind the terminal projecting 25mm 

beyond the external edges of the terminal.

Summary of Contents for E4-35

Page 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device K U D O S...

Page 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Page 3: ...G WALLS 7 6 FIRE SAFE INSTALLATION 8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS WITH FLAMMABLE MATERIALS 8 6 2 1 FLOOR PROTECTION 8 6 2 2 RADIATION...

Page 4: ...ORS CODES PROCONTROL APP 24 B A MESSAGES SHOWN IN APP 24 B B MESSAGES SHOWN IN REMOTE 25 C FAULTS AND ERROR CODES IN THE REMOTE 26 C A F41 ERROR 26 C B ROUTER INFORMATION 26 C B A MINIMUM REQUIREMENT...

Page 5: ...ke sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used with the type of gas spec...

Page 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Page 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Page 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Page 9: ...contain flammable building materials and all walls on which flammable objects e g built in furniture or wooden panels are mounted on the side of the wall that is turned away from the fireplace Walls c...

Page 10: ...ombustible materials Top A a a H G Figure 6 1 Distances to combustible materials front B A a a C E D Figure 6 2 Floor plate Letter Minimum Distance to flammable materials mm A 120 B 350 C 300 D 600 E...

Page 11: ...ach category refers to a set of tables 1 A table for horizontal outlet 2 A table for vertical outlet You must use the table applicable to you You calculate your total vertical section TVS as well as y...

Page 12: ...L Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit In a situtation of non combustible materials keep a distance of at least 5...

Page 13: ...vice for a period of one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features an eco setting The amount of users that...

Page 14: ...e test points on the gas valve can be reached and the relevant button can also be reached for a reset of the receiver 9 3 THE COMBUSTION CHAMBER The glass must be removed to enter the combustion chamb...

Page 15: ...NSTALLATION MANUAL Figure 9 2 Front view after glass removal Figure 9 3 Gas control in brackets under fireplace Figure 9 4 Hooks on windows 1 2 Figure 9 5 Removal of front frame 1 2 Figure 9 1 Positio...

Page 16: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 6 2 PILOT The pilot flame...

Page 17: ...peration of the appliance 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed with heat resistant ceramic fibers or artificial glassy silicate fibers Excessive exposure to t...

Page 18: ...rid and place the indicated logs in the correct place on the grid For the rest of the logs it is important that the grate is not too full If necessary adjust the position of the decoration material if...

Page 19: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Page 20: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Page 21: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Page 22: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Page 23: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Page 24: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Page 25: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Page 26: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Page 27: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Page 28: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Page 29: ...O O V V 6 O O O O O O V V 5 O O O O O O V V 4 O O O O O O V V 3 5 O O O O O O V V 3 V V V V V V V V 2 5 V V V V V V V V 2 V V V V V V V V 1 5 V V V V V V V X 1 V V V V V X X X 0 5 X V V X X X X X 0 1...

Page 30: ...ner 1x 140 FlatBurner 2x 160 LogBurner 1x 120 FlatBurner Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode e...

Page 31: ...longs to G A ECOLABELS The ecolabels for the different types of gas are indicated below respectively G20 G25 and G30 From 2022 the UKCA label is used for the United Kingdom Both versions may be found...

Page 32: ...awings of the fireplace with some of the important dimensions that you have to take into account when installing and installing your fireplace 710 50 704 00 350 00 270 00 80 00 550 00 19 00 588 00 483...

Page 33: ...Info element4 nl www element4 nl 19 01 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Reviews: