Element4 E4-35 Installation Manual Download Page 26

2 5

Appendix B 

I N S T A L L A T I O N   M A N U A L   |

Error code  Message in App

Description

Possible cause

F26

Contact Service.

• 

It is not possible to increase flame height 

after ignition

• 

Fan at level 4 for 10 minutes (T > 80 °C)

• 

Receiver powered by batteries and Receiver temperature 
exceeds 60°C

• 

Receiver powered by mains power and Receiver temperature 
exceeds 80°C

F27

Contact Service.

• 

Fire is not responding

• 

No electronic control of fire

• 

No  handset  or  Wi-Fi  Box  connected  to  Receiver  for  more 

than 3 hours

F28

On-Demand Pilot

• 

Pilot shuts off after a predefined time

• 

Pilot shuts off after no motor movement for a predetermined 

time

F31

Contact Service.

• 

Fire is not responding

• 

No electronic control of fire

• 

Receiver or Wi-Fi Box malfunction

• 

Connection cable from Receiver to Wi-Fi Box defective

F41

Check Wi-Fi

• 

Fire is not responding

• 

No electronic control of fire

• 

No Wi-Fi connection to myfire Wi-Fi Box, router and / or 

smart device

• 

Wi-Fi in smart device is deactivated

F42

Check Wi-Fi

• 

Fire is not responding

• 

No electronic control of fire

• 

No power to router

• 

No Wi-Fi connection to router and / or smart device

 

Smart device not in the correct home network

F43

No Receiver 

Connected. 

Contact Service.

• 

Fire is not responding

• 

No electronic control of fire

• 

No communication between Receiver and myfire Wi-Fi Box

F44

Contact Service.

• 

No temperature shown in App

• 

N.a. (not applicable) displayed in App

• 

Handset not within range

 

Low battery power in handset

F49

Contact Service.

• 

No electronic control of fire

• 

Receiver software < 8.32 is not supported by myfire Wi-Fi 

Box Version 2

F50

Contact Service.

• 

No electronic control of fire

• 

Handset software < SW 231 is not supported by the myfire 
Wi-Fi Box Version 2

B�B 

MESSAGES SHOWN IN REMOTE

Error 

code 

App 

Message

Time

Description

Possible Cause

F04

F04

4 sec.

• 

No pilot flame within 30 sec.

• 

NOTE:  After  3  failed  ignition  sequences  F06 

shown

• 

No gas supply

• 

Air in pilot supply line

• 

No spark

• 

Reversed polarity in thermocouple wiring

F06

F06

4 sec.

• 

3 failed ignition sequences within 5 minutes

• 

Fire is not responding; no pilot flame

• 

No gas supply

• 

Air in pilot supply line

• 

No spark

• 

Reversed polarity in thermocouple wiring

• 

Check for correct pilot orifice (LPG to NG or vice versa)

F07

F07

Until 

batteries 

replaced

• 

Battery icon flashes on handset display

• 

Low battery power in handset

F09

F09

4 sec.

• 

Fire is not responding

• 

No electronic control of fire

• 

Down arrow button was not pressed during pairing

• 

Receiver and handset are not synced

F46

F46

4 sec.

• 

Fire is not responding

• 

Intermittent response

• 

No electronic control of fire

• 

No or bad connection between receiver and handset

• 

No power at Receiver (batteries low) 

• 

Mains  adapter  faulty,  set  not  communicating  with 

Receiver)

Summary of Contents for E4-35

Page 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device K U D O S...

Page 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Page 3: ...G WALLS 7 6 FIRE SAFE INSTALLATION 8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS WITH FLAMMABLE MATERIALS 8 6 2 1 FLOOR PROTECTION 8 6 2 2 RADIATION...

Page 4: ...ORS CODES PROCONTROL APP 24 B A MESSAGES SHOWN IN APP 24 B B MESSAGES SHOWN IN REMOTE 25 C FAULTS AND ERROR CODES IN THE REMOTE 26 C A F41 ERROR 26 C B ROUTER INFORMATION 26 C B A MINIMUM REQUIREMENT...

Page 5: ...ke sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used with the type of gas spec...

Page 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Page 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Page 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Page 9: ...contain flammable building materials and all walls on which flammable objects e g built in furniture or wooden panels are mounted on the side of the wall that is turned away from the fireplace Walls c...

Page 10: ...ombustible materials Top A a a H G Figure 6 1 Distances to combustible materials front B A a a C E D Figure 6 2 Floor plate Letter Minimum Distance to flammable materials mm A 120 B 350 C 300 D 600 E...

Page 11: ...ach category refers to a set of tables 1 A table for horizontal outlet 2 A table for vertical outlet You must use the table applicable to you You calculate your total vertical section TVS as well as y...

Page 12: ...L Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit In a situtation of non combustible materials keep a distance of at least 5...

Page 13: ...vice for a period of one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features an eco setting The amount of users that...

Page 14: ...e test points on the gas valve can be reached and the relevant button can also be reached for a reset of the receiver 9 3 THE COMBUSTION CHAMBER The glass must be removed to enter the combustion chamb...

Page 15: ...NSTALLATION MANUAL Figure 9 2 Front view after glass removal Figure 9 3 Gas control in brackets under fireplace Figure 9 4 Hooks on windows 1 2 Figure 9 5 Removal of front frame 1 2 Figure 9 1 Positio...

Page 16: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 6 2 PILOT The pilot flame...

Page 17: ...peration of the appliance 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed with heat resistant ceramic fibers or artificial glassy silicate fibers Excessive exposure to t...

Page 18: ...rid and place the indicated logs in the correct place on the grid For the rest of the logs it is important that the grate is not too full If necessary adjust the position of the decoration material if...

Page 19: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Page 20: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Page 21: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Page 22: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Page 23: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Page 24: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Page 25: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Page 26: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Page 27: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Page 28: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Page 29: ...O O V V 6 O O O O O O V V 5 O O O O O O V V 4 O O O O O O V V 3 5 O O O O O O V V 3 V V V V V V V V 2 5 V V V V V V V V 2 V V V V V V V V 1 5 V V V V V V V X 1 V V V V V X X X 0 5 X V V X X X X X 0 1...

Page 30: ...ner 1x 140 FlatBurner 2x 160 LogBurner 1x 120 FlatBurner Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode e...

Page 31: ...longs to G A ECOLABELS The ecolabels for the different types of gas are indicated below respectively G20 G25 and G30 From 2022 the UKCA label is used for the United Kingdom Both versions may be found...

Page 32: ...awings of the fireplace with some of the important dimensions that you have to take into account when installing and installing your fireplace 710 50 704 00 350 00 270 00 80 00 550 00 19 00 588 00 483...

Page 33: ...Info element4 nl www element4 nl 19 01 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Reviews: