background image

INSTALLATION MANUAL

PLEASE LEAVE THESE INSTRUCTIONS BEHIND WITH THE DEVICE

C U P I D O   6 0   &   C U P I D O   7 0

C O N V E N T I O N A L   F L U E   F I R E S

Summary of Contents for Cupido 60 CF

Page 1: ...INSTALLATION MANUAL PLEASE LEAVE THESE INSTRUCTIONS BEHIND WITH THE DEVICE C U P I D O 6 0 C U P I D O 7 0 C O N V E N T I O N A L F L U E F I R E S...

Page 2: ...INSTALLATION MANUAL 2 DO NOT USE THIS PRODUCT AS A PRIMARY HEAT SOURCE...

Page 3: ...on 11 8 2 Checking the gas lines 11 9 ELECTRICAL CIRCUIT 12 9 1 Domotica 12 9 2 Element4 ProControl App 12 10 MAINTENANCE INSTRUCTION 13 10 1 Maintenance in the combustion chamber 13 10 2 Cleaning the...

Page 4: ...ance acts as a fireguard conformingtoBS 1945 1971andsatisfiestheHeatingAppliance Fireguards regulations 1991 No part of the window or frame should be permanently removed It does not give protection fo...

Page 5: ...by a competent installer according to the rules and regulations that are applicable in the country or even region of installation and those as described in this manual 2 There is a warranty period of...

Page 6: ...ng the pilot light Check that the control knob A is in the ON position Fig 4 3 Press the button on off button of your remote control and continue to hold down 3 to 5 sec until you hear two short beepe...

Page 7: ...uld apply to the local norms in force Calculate the diamater of the gas flue such that no pressure loss is occuring in the pipes Place a shut off valve in the near vicinity of the device Position the...

Page 8: ...the cove It is important to follow the installation regulations below carefully Whentheregulationsareinsufficiently ornotprovided with the aspects of fire safety the instructions according to NPR 3378...

Page 9: ...on material or other to pack the void around or above the appliance 6 4 Flue Connection 6 4 1 General notes This appliance may be installed with a roof termination with a rigid or flexible pipes or in...

Page 10: ...glass and any flammable material in front of the fireplace is one meter If a shelf is to be fitted above the fireplace opening a gap of 150mm minimum should be left between the opening and the shelf...

Page 11: ...ting You can use an adjustable pipe and roof fitting Figure 8 1 Gas Block Measuring Points 8 INSTALLATION CHECK AND FIRST USAGE 8 1 Renovation new construction When firing up the device for the first...

Page 12: ...1 1 Remove the ropes holding the window in place See Figure 10 4 Put the section cup on the glass and make sure it is properly vaccuumed so it will not come off See Figure 10 5 Lift the glass out of t...

Page 13: ...INSTALLATION MANUAL 13 2 Figure 10 6 Remove window by tilting Figure 10 4 Remove window ropes 1 Figure 10 5 Put on the suction cup and lift window Figure 10 3 Remove bottom trim...

Page 14: ...d with the correct receiver and remote combination Necessities for the installation of the ProControl 220 volt electricty near the fire Wi Fi code of the router Smart Phone or tablet ProControl manual...

Page 15: ...with this appliance are to be used The ceramics must be laid only as shown on this page Replacement parts are available from your dealer but should only be installed by a qualified installation engine...

Page 16: ...nformation about the responsible disposal of discarded appliances 12 USER INSTRUCTION We recommend that you have the appliance inspected annually by a recognized installer to ensure safe use and a lon...

Page 17: ...e surface of the pilot The fittings on the under side of the pilot can be un done using a 10mm spanner where appropriate To access the Main Burner Injectors the Burner base units must be removed This...

Page 18: ...disturbs the reception Change the position of the antenna See Figure A 4 C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver g...

Page 19: ...NDICES 19 40mm Figure A 7 Pilot set Figure A 2 Bend pin Figure A 4 Antenna Figure A 6 Testpoint A Figure A 1 RESET button AM PM ON 1 2 OFF Figure A 3 Double plus button on the remote Figure A 5 Torx s...

Page 20: ...ect Replace thermocouple Tip Always use a new pressure piece when a thermocouple is replaced H Receiver gives 3 short beeps after each command 1 Batteries in the receiver are empty Replace the batteri...

Page 21: ...1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main Burner Ignite second burner Extinguish second burner 1 3 1 3 1 2 3 1 2 2 3 CONTACT Cable RECEIVER Figure A 12 Domoti...

Page 22: ...sition Gas ports for burner are blocked F12 Contact Service Motor turns to pilot position Receiver powered by batteries and Receiver temperature exceeds 60 C Check air circulation and heat shield F13...

Page 23: ...pported by myfire Wi Fi Box Version 2 F50 Contact Service No electronic control of fire Handset software SW 231 is not supported by the myfire Wi Fi Box Version 2 B 2 Messages shown in remote Error co...

Page 24: ...ces from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much spac...

Page 25: ...pply flows through a used room 3 A window that can be opened and located in the vicinity of a used room toilet or bathroom If the required distance is not feasible the rules regarding the exit positio...

Page 26: ...x 100 Angle 1 x 100 Straight Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode elsb 9 5 kW Power requirement...

Page 27: ...W ENERGIA ENERGIJA ENERGY ENERGIE A A A A A C Cupido 60 CF G30 6 1 A A B C D E F G 2015 1186 kW ENERGIA ENERGIJA ENERGY ENERGIE A A A A A C Cupido 70 CF G30 6 1 A A B C D E F G 2015 1186 kW ENERGIA EN...

Page 28: ...are two possible exhaust ports respecively on top and on the back of the fireplace One of the both needs to be open the other is than closed off The top flue exhaust can be used to attached a flue pip...

Page 29: ...APPENDICES 29 Figure I 1 Technical drawing of Cupido 60 CF...

Page 30: ...APPENDICES 30 Figure I 2 Technical drawing of Cupido 70 CF...

Page 31: ......

Page 32: ...Paxtonstraat 23 8013 RP Zwolle The Netherlands Info element4 nl www element4fires com RELEASE DATE 10 01 20 ELEMENT 4 B V...

Reviews: