Setting
Description
DC output after remote
Determines the condition of the DC output after leaving remote control either manu-
ally or by command.
•
OFF
= DC output will be always off when switching from remote to manual
•
AUTO
= DC output will keep the last condition
Enable R mode
Activates (“
Yes
”) or deactivates (“
No
”) the internal resistance control. If activated,
the resistance set value of the simulated internal resistor can be adjusted addition-
ally to the other set values. For more refer to
„3.2.4. Internal resistance regulation“
„3.4.6. Manual adjustment of set values“
USB file separator format
Switches the decimal point format of values and also the CSV file separator for USB
logging (see
) and for other features where CSV files are used.
US
= Comma separator (US standard for CSV files)
Default
= Semicolon separator (german/european standard for CSV files)
USB logging with units
(V,A,W)
CSV files generated from USB logging by default add physical units to values. This
can be deactivated by setting this option to “
No
”
Calibrate device
Touch area “
Start
” starts a calibration routine (see
), but only if the
device is in U/I/P mode, i.e. R mode not activated.
Reset device to defaults
Touch area “
Start
” will initiate a reset of all settings (HMI, profile etc.) to default
values, as shown in the menu structure diagrams on the previous pages, and all
set values to 0
Restart device
Will initiate a warm start of the device
3.4.3.2
Menu “User Events”
See
„3.6.2.1 User defined events“ on page 58
3.4.3.3
Menu “Profiles”
See
„3.9 Loading and saving an user profile“ on page 60
.
3.4.3.4
Menu “Overview”
This menu page displays an overview of the set values (U, I, P or U, I, P, R) and alarm settings as well as settings
limits. These can only be displayed, not changed.
3.4.3.5
Menu “About HW, SW...”
This menu page displays an overview of device relevant data such as serial number, article number etc., as well as
an alarm history which lists the number of device alarms that probably occurred since the device has been powered.
3.4.3.6
Menu “Function Generator”
See
„3.10 The function generator“ on page 61.
3.4.3.7
Menu “Communication”
Here settings for the Ethernet port are configured. The USB port there doesn’t require any settings.
After delivery or a complete reset, the Ethernet port has following
default settings
assigned:
•
DHCP: off
•
IP: 192.168.0.2
•
Subnet mask: 255.255.255.0
•
Gateway: 192.168.0.1
•
Port: 5025
•
DNS: 0.0.0.0
•
Host name: Client (configurable via HMI)
•
Domain: Workgroup (configurable via HMI)
Those settings can be changed anytime and configured to meet local requirements. Furthermore, there are global
communication settings available regarding timing and protocols.