Page 11
EA Elektro-Automatik GmbH
Helmholtzstr. 31-37 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ELR 9000 HP Series
5 kW
Model HP
ELR 9080-170 ELR 9200-70
ELR 9360-40
ELR 9500-30
ELR 9750-20
Analog interface
(1
Set value inputs
U, I, P, R
Actual value output
U, I
Control signals
DC input on/off, remote control on/off, R mode on/off
Status signals
CV, OVP, OT
Galvanic isolation to the device max. 1500 V DC
Sample rate (set value inputs)
500 Hz
Insulation
Allowed potential shift (floating voltage) on the DC input:
Input (DC) to enclosure
±400 V DC
±725 V DC
±725 V DC
±1500 V DC
±1500 V DC
Input (AC) to input (DC)
±400 V DC
±1000 V DC
±1000 V DC
±1800 V DC
±1800 V DC
Environment
Cooling
Temperature controlled fans
Ambient temperature
0..50 °C (32...122°F)
Storage temperature
-20...70 °C (-4...158°F)
Digital interfaces
Featured
1x USB-B for communication, 1x USB-A for functions and logging, 1x Master-slave bus,
1x GPIB (optional)
Interface modules slot
(2
optional: CANopen, Profibus, Profinet, RS232, CAN, Ethernet, ModBus TCP, EtherCAT
Galvanic isolation to the device max. 1500 V DC
Terminals
Rear side
Share Bus, DC input, AC input/output, remote sensing, analog interface, USB-B,
master-slave bus, Interface module slot
Front side
USB-A
Dimensions
Enclosure (WxHxD)
19“ x 3U x 668 mm (26.3”)
Total (WxHxD)
483 mm x 133 mm x 775 mm (19” x 5.2” x 30.5”)
Standards
EN 61010-1:2011-07, EN 50160:2011-02 (grid class 2), EN 61000-6-2:2016-05,
EN 61000-6-3:2011-09 (radiation class B)
Weight
~18 kg (39.7 lb) ~18 kg (39.7 lb) ~18 kg (39.7 lb) ~18 kg (39.7 lb) ~18 kg (39.7 lb)
Article number
(3
33200435
33200436
33200437
33200438
33200439
(1 For technical specifications of the analog interface see
„3.5.4.4 Analog interface specification“ on page 57
(2 Only in the standard version
(3 Article number of the standard version, devices with options will have a different number