PS 2000 B Triple Series

4. 

Service and maintenance

4.1 

Maintenance / cleaning

The device needs no maintenance. Models with a fan may require cleaning the fan. The frequency of cleanse is 

depending on the ambient conditions. The fan serves to cool the components which are heated by the inherent 

high dissipation of energy. A heavily dirt filled fan can lead to insufficient airflow and therefore the DC outputs 1 

and/or 2 could switch off too early due to overheating or possibly lead to defects.

Cleaning the internal fan can be performed with a vacuum cleaner or a brush and from the outside.

4.2 

Fault finding / diagnosis / repair

If the equipment suddenly performs in an unexpected way, which indicates a fault, or it has an obvious defect, this 

can not and must not be repaired by the user. Contact the supplier in case of suspicion and elicit the steps to be 

taken.
It will then usually be necessary to return the device to Elektro-Automatik  (with or without warranty). If a return for 

checking or repair is to be carried out, ensure that:

• 

the supplier has been contacted and it’s clarified how and where the equipment should be sent.

• 

the device is in fully assembled state and in suitable transport packaging, ideally the original packaging.

• 

a fault description in as much detail as possible is attached.

• 

if shipping destination is abroad, the necessary customs papers are attached.

4.2.1  Replacing a defect mains fuse

The device is protected by a fusible which is inside a fuse holder on the rear of the device. The fuse rating is printed 

next to the fuse holder. Replace the fuse only with one of same size and rating.

4.2.2  Firmware updates

Firmware updates should only be installed when they can eliminate existing bugs in the firm

-

ware in the device or contain new features. 

The firmware of the control panel (HMI) and the power board (DR/LT) can be updated, if necessary. For this the 

software “EA Power Control” is needed, which is included on the supplied USB stick or available as download from 

our website, together with the firmware update.

5. 

Contact and support

5.1 

Repairs

Repairs, if not otherwise arranged between supplier and customer, will be carried out by EA Elektro-Automatik. 

For this the equipment must generally be returned to the manufacturer. No RMA number is needed. It’s sufficient 

to package the equipment adequately and send it, together with a detailed description of the fault and, if still under 

guarantee, a copy of the invoice, to the following address.

5.2 

Contact options

Questions or problems with operation of the device, use of optional components, with the documentation or soft-

ware, can be addressed to technical support either by telephone or e-Mail.

Address

e-Mail

Telephone

EA Elektro-Automatik
Helmholtzstr. 31-37
41747 Viersen
Germany

Technical support:
[email protected]
All other topics:
[email protected]

Switchboard: +49 2162 / 37850
Support: +49 2162 / 378566

Summary of Contents for 39 200 120

Page 1: ...Elektro Automatik PS 2000 B TFT Triple DC Power Supply Operating Manual Doc ID PS2TEN Revision 14 Date 11 2020...

Page 2: ......

Page 3: ...res before installation and use 14 2 3 2 Preparation 14 2 3 3 Installing the device 14 2 3 4 Connection to DC loads 15 2 3 5 Grounding of the DC outputs 15 2 3 6 Connecting the USB port 15 3 OPERATION...

Page 4: ...as well as general notices in this document are shown in a box with a symbol as follows Symbol for a life threatening danger Symbol for general safety notices instructions and damage protection bans S...

Page 5: ...B Construction Version B Second generation Maximum current of the device in Ampere Maximum voltage of the device in Volt Special marking 3 Three outputs triple Series 2 Series 2000 Type identification...

Page 6: ...ulations must be applied when plugging interface cards or modules into the relative slot Interface cards or modules may only be attached or removed after the device is switched off It s not necessary...

Page 7: ...he responsibilities for operation maintenance and cleaning of the equipment ensure that all employees who use the equipment have read and understood the manual Furthermore the users are to be regularl...

Page 8: ...pair of DC output sockets and is called output 2 The upper pair of DC output sockets form output 3 The meaning of the signals on the display of output 1 and 2 is as follows Signal OT OverTemperature...

Page 9: ...P 24 mVRMS Output 1 2 Current Adjustment range 0 6 A 0 10 A 0 3 A 0 5 A Accuracy 1 at 23 5 C 0 3 IMax 0 3 IMax 0 3 IMax 0 3 IMax Load regulation at 0 100 UOUT 0 15 IMax 0 15 IMax 0 15 IMax 0 15 IMax O...

Page 10: ...Automatik GmbH Helmholtzstr 31 37 41747 Viersen Germany Fon 49 2162 3785 0 Fax 49 2162 16230 www elektroautomatik de ea1974 elektroautomatik de PS 2000 B Triple Series 1 8 4 Views Figure 1 Front side...

Page 11: ...alue or adjustment of parameter value in the menu Push selection of the decimal position cursor of the currently assigned value 7 Pushbutton On Off Used to switch the DC output oon or off unless the H...

Page 12: ...es For these devices the following accessories are available Multi Control license Ordering numbers Single license 33 100 229 5 pack of licenses 33 100 230 The device is delivered with an USB stick th...

Page 13: ...tatus display lower part This area displays various status texts and symbols Display Description The HMI is locked The HMI is unlocked Remote The device is under remote control via USB Alarm xxx Alarm...

Page 14: ...3 1 Safety procedures before installation and use Before connecting to the mains ensure that the connection is as shown on the product label Overvoltage on the AC supply can cause equipment damage In...

Page 15: ...ding of the DC outputs The metal socket in proximity to output 1 is internally wired to PE and can be used to ground one of the DC output poles of all three outputs by direct connection or it can be u...

Page 16: ...e Voltage regulation is also called constant voltage operation CV The DC output voltage of a power supply is held constant on the adjusted value unless the output current reaches the adjusted current...

Page 17: ...will be in constant voltage mode If however the actual current reaches the set value of current the device will switch automatically to current limiting While the DC output is switched on and constan...

Page 18: ...ltage alarm OVP will switch off the DC output and can occur if the power supply itself as a voltage source generates an output voltage higher than set for the overvoltage alarm threshold OVP 0 110 UNo...

Page 19: ...or a blackout doesn t leave the device enough time to store the latest values It s practically powered down immediately Thus the device stores the set values and all settings automatically when they...

Page 20: ...left HMI Element Description In right HMI Language Selection of the display language between German and English Default setting English No Backlight The choice here is whether the backlight remains Al...

Page 21: ...bs 1 With the main display being shown it means no menu mode is active turn the left hand knob to adjust the output voltage and the right hand knob to adjust the output current This doesn t depend on...

Page 22: ...How to lock the HMI with PIN Don t activate the PIN lock if you are unsure about the current PIN It can be changed but only if the current PIN is entered Resetting the device via remote command will a...

Page 23: ...ivated tracking is saved along with other device settings and thus instantly restored after powering the device Even in tracking mode the two outputs can have separate alarms which would always lead t...

Page 24: ...t used the serial current is limited by the output with the lower current set value Series connection of multiple devices isn t permitted because the total voltage could exceed the voltage withstand o...

Page 25: ...considered completely differently to the other outputs It s meant to be an auxiliary output with a fixed voltage which is barely adjustable ca 3 to ca 6 V with a trimmer That trimmer is placed between...

Page 26: ...can try to acknowledge and delete the alarm by pressing button On Off In order to acknowledge an alarm during remote control see the programming guide These device alarms are configurable Alarm Meani...

Page 27: ...detail as possible is attached if shipping destination is abroad the necessary customs papers are attached 4 2 1 Replacing a defect mains fuse The device is protected by a fusible which is inside a f...

Page 28: ...EA Elektro Automatik GmbH Co KG Development Production Sales Helmholtzstra e 31 37 41747 Viersen Germany Fon 49 2162 37 85 0 Telefax 49 2162 16 230 ea1974 elektroautomatik de www elektroautomatik de...

Reviews: