PS 2000 B Triple Series

3.4.4  Adjustment limits

Adjustment limits only affect the set values, no matter if during manual adjustment or remote 

control!

Defaults are that the set values of voltage and current are adjustable 

from 0 to 100% of the rated value. This may be obstructive in some 

cases, especially for protection of applications against overvoltage 

which may occur when accidentally adjusting the voltage too high. 

Therefore upper limits for current (I) and voltage (U) can be set which 

limit the range of the set value adjustment.

 

► How to configure the adjustment limits

1. 

While the DC output (1 or 2) is switched off, press button 

Settings

.

2. 

In the menu use the left knob to navigate to 

Settings

 and press the left knob.

3. 

In menu 

Settings

 use the left knob again to select 

U-max

 (upper limit of voltage) or 

I-max

 (upper limit of 

current). Adjust the value as desired.

The limits can only be equal to or higher than the related set value. Thus it might be re-

quired to turn down the set value before you can finally turn the limit down to the desired 

level. The set values are accessible on the same menu page.

4. 

Leave the setup menu.

3.4.5  Manual adjustment of set values

Adjustment of voltage and current is the fundamental operation of this series’ power supplies. In manual control, 

the set values can only be adjusted with the rotary knobs.

When adjusting the set values, an upper limit could interfere. Also see section «3.4.4. Adjust-

ment limits». Once a limit is reached, the main screen will show a note like “Limit: U-Max” for 

1.5 seconds above the set value. 

 

How to adjust values with the rotary knobs

1. 

With the main display being shown, it means no menu mode is active, turn the left-hand knob to adjust 

the output voltage and the right-hand knob to adjust the output current. This doesn’t depend on DC output 

condition. Both set values affect each other (see section 

«3.2.3. Power limitation»

 for the background). If 

you would, for example, turn up the voltage then the current value would automatically start to decrease at 

some point until the max. adjustable voltage is reached. The same would happen vice versa when starting 

to turn the current set value again. The voltage value would then immediately start to decrease while the 

current value increases at the same time.

2. 

Selecting a digit is done by pushing the rotary knob which shifts the cursor from right to left (selected digit 

will be underlined).

3.4.6 

Switching the DC output on or off

The DC output of the device can be manually or remotely switched on and off. In manual operation this can be 

restricted by the control panel being locked.

 

► How to manually switch the DC output on or off

1. 

As long as the control panel (HMI) isn’t fully locked (see 

«3.4.7. Control panel (HMI) lock»

 about the HMI lock 

options) press button 

On/Off

. Otherwise you are asked to disable the HMI lock, which is done by pushing 

the knob as confirmation. If the PIN has been activated in menu “

HMI Setup

”, you would then be asked to 

enter the PIN to complete the unlocking process.

2. 

The 

On/Off

 button toggles the DC output condition between on and off, as long as a change isn’t restricted 

by any alarm or the device being in remote control. The DC output condition is indicated by the LED and a 

text (green = on, red = off) in the status area of the display.

 

► How to remotely switch the DC output on or off via the digital interface

1. 

See the programming guide on the included USB stick if you are creating custom software or refer to the 

documentation of the included LabView VI set or further documentation provided by EA Elektro-Automatik.

Summary of Contents for 39 200 120

Page 1: ...Elektro Automatik PS 2000 B TFT Triple DC Power Supply Operating Manual Doc ID PS2TEN Revision 14 Date 11 2020...

Page 2: ......

Page 3: ...res before installation and use 14 2 3 2 Preparation 14 2 3 3 Installing the device 14 2 3 4 Connection to DC loads 15 2 3 5 Grounding of the DC outputs 15 2 3 6 Connecting the USB port 15 3 OPERATION...

Page 4: ...as well as general notices in this document are shown in a box with a symbol as follows Symbol for a life threatening danger Symbol for general safety notices instructions and damage protection bans S...

Page 5: ...B Construction Version B Second generation Maximum current of the device in Ampere Maximum voltage of the device in Volt Special marking 3 Three outputs triple Series 2 Series 2000 Type identification...

Page 6: ...ulations must be applied when plugging interface cards or modules into the relative slot Interface cards or modules may only be attached or removed after the device is switched off It s not necessary...

Page 7: ...he responsibilities for operation maintenance and cleaning of the equipment ensure that all employees who use the equipment have read and understood the manual Furthermore the users are to be regularl...

Page 8: ...pair of DC output sockets and is called output 2 The upper pair of DC output sockets form output 3 The meaning of the signals on the display of output 1 and 2 is as follows Signal OT OverTemperature...

Page 9: ...P 24 mVRMS Output 1 2 Current Adjustment range 0 6 A 0 10 A 0 3 A 0 5 A Accuracy 1 at 23 5 C 0 3 IMax 0 3 IMax 0 3 IMax 0 3 IMax Load regulation at 0 100 UOUT 0 15 IMax 0 15 IMax 0 15 IMax 0 15 IMax O...

Page 10: ...Automatik GmbH Helmholtzstr 31 37 41747 Viersen Germany Fon 49 2162 3785 0 Fax 49 2162 16230 www elektroautomatik de ea1974 elektroautomatik de PS 2000 B Triple Series 1 8 4 Views Figure 1 Front side...

Page 11: ...alue or adjustment of parameter value in the menu Push selection of the decimal position cursor of the currently assigned value 7 Pushbutton On Off Used to switch the DC output oon or off unless the H...

Page 12: ...es For these devices the following accessories are available Multi Control license Ordering numbers Single license 33 100 229 5 pack of licenses 33 100 230 The device is delivered with an USB stick th...

Page 13: ...tatus display lower part This area displays various status texts and symbols Display Description The HMI is locked The HMI is unlocked Remote The device is under remote control via USB Alarm xxx Alarm...

Page 14: ...3 1 Safety procedures before installation and use Before connecting to the mains ensure that the connection is as shown on the product label Overvoltage on the AC supply can cause equipment damage In...

Page 15: ...ding of the DC outputs The metal socket in proximity to output 1 is internally wired to PE and can be used to ground one of the DC output poles of all three outputs by direct connection or it can be u...

Page 16: ...e Voltage regulation is also called constant voltage operation CV The DC output voltage of a power supply is held constant on the adjusted value unless the output current reaches the adjusted current...

Page 17: ...will be in constant voltage mode If however the actual current reaches the set value of current the device will switch automatically to current limiting While the DC output is switched on and constan...

Page 18: ...ltage alarm OVP will switch off the DC output and can occur if the power supply itself as a voltage source generates an output voltage higher than set for the overvoltage alarm threshold OVP 0 110 UNo...

Page 19: ...or a blackout doesn t leave the device enough time to store the latest values It s practically powered down immediately Thus the device stores the set values and all settings automatically when they...

Page 20: ...left HMI Element Description In right HMI Language Selection of the display language between German and English Default setting English No Backlight The choice here is whether the backlight remains Al...

Page 21: ...bs 1 With the main display being shown it means no menu mode is active turn the left hand knob to adjust the output voltage and the right hand knob to adjust the output current This doesn t depend on...

Page 22: ...How to lock the HMI with PIN Don t activate the PIN lock if you are unsure about the current PIN It can be changed but only if the current PIN is entered Resetting the device via remote command will a...

Page 23: ...ivated tracking is saved along with other device settings and thus instantly restored after powering the device Even in tracking mode the two outputs can have separate alarms which would always lead t...

Page 24: ...t used the serial current is limited by the output with the lower current set value Series connection of multiple devices isn t permitted because the total voltage could exceed the voltage withstand o...

Page 25: ...considered completely differently to the other outputs It s meant to be an auxiliary output with a fixed voltage which is barely adjustable ca 3 to ca 6 V with a trimmer That trimmer is placed between...

Page 26: ...can try to acknowledge and delete the alarm by pressing button On Off In order to acknowledge an alarm during remote control see the programming guide These device alarms are configurable Alarm Meani...

Page 27: ...detail as possible is attached if shipping destination is abroad the necessary customs papers are attached 4 2 1 Replacing a defect mains fuse The device is protected by a fusible which is inside a f...

Page 28: ...EA Elektro Automatik GmbH Co KG Development Production Sales Helmholtzstra e 31 37 41747 Viersen Germany Fon 49 2162 37 85 0 Telefax 49 2162 16 230 ea1974 elektroautomatik de www elektroautomatik de...

Reviews: