background image

12

Operating and assembly instructions SD

www.elektror.com

0241

18 07.16/06

EN

Note!

The eye bolt on the motor must not be used to 

lift the entire blower. This is unsed if the motor 

needs to be (dis-)assembled.

2.2 Storage

•  Ensure that the air intake connection and pressure 

  connection are closed. 
•  Store the side channel blower

  -> in its original packaging if possible

  -> in a closed room 

  -> in a dry, dust-free and vibration-free area.
•  Storage temperature range from -20°C to +60°C
•  After a storage period of 6 months, the bearings should 

  be checked before they are mounted in the side channel 

 blower.

3 INFORMATION ON COMMISSIONING 
THE MACHINE

3.1 Basic information

• Prior to the 

fi

 rst start-up and before any other start-up, the

  proper operating status of the unit must be inspected. Units 

  that, for example, are found to be defective upon delivery 

  or during installation, must be examined by quali

fi

 ed tech-

 nicians.
• Installation, assembly and operation must only be per-

  formed by properly trained and quali

fi

 ed specialists. Op-

 eration following incorrect installation, maintenance or 

  unapproved replacement of components constitutes non-

  designated use and renders the warranty void. The result-

  ant risk shall be borne solely by the customer or owner.

3.2  Installation and assembly

•  Protect the side channel blower from the weather and 

  install it in a horizontal position - see also 1.1. For outdoor 

  use, protection from the weather must generally be pro-

  vided that ful

fi

 ls the requirements listed in 1.1 Intended 

  Use and protects the side channel blower from the in

fl

 u-

  ences of the weather.
•  Do not expose to vibrations or shocks. Permissible 

  vibrational load on side channel blower: refer to ISO  

 14694, BV-3.
•  Standard side channel blowers with base: Bolt securely  

  to a level and 

fi

 rm surface at the place of use, making 

  sure that the surface has adequate load-bearing capacity 

  and avoiding vibration transmission or vibrational load.
• Side channel blowers placed on the rubber elements 

  provided must be secured against turning.

•  Blowers with motor (drive), belt drive and belt guard: The 

  buyer (plant manufacturer, operating company or other 

  customer) is solely responsible for safe, stable installation 

  and fastening in conjunction with the motor, belt drive and 

  belt guard to be provided by the customer, and for compli-

  ance with applicable standards and speci

fi

 cations.

•  Cover open intakes or outlets with protective grating 

  according to DIN EN ISO 13857.
•  The belt drive and rotating parts must be covered with a 

  belt guard according to DIN EN ISO 13857.
•  Ensure adequate motor ventilation. Permissible ambient 

 temperatures:
Special voltages, multi-voltage motors, FU compatible ver-

sions, FUK versions, UL certi

fi

 ed appliances:

   • Ambient temperature -20°C to +40°C
•  The performance of the drive motor’s ventilation system 

  must not be impaired by the installation situation.

3.3 Electrical connection

Note!

The work described in this section may only be 

performed by a quali

fi

 ed electrician. Connect the 

appliance to the power supply in the terminal box 

as per the wiring diagram and in compliance with 

the applicable local regulations.

Three-phase or a.c. motors can be used as drive motors. 

In the appliance designation, the letter D stands for three-

phase a.c. and the letter E for single-phase a.c.
•  The drive motor must be protected using a motor overload 

  switch (this does not apply to frequency converter oper-

  ated appliances). Where appliances are frequency-

  converter-operated, the existing temperature sensor 

  (PTC resistor sensor) or temperature switch (normally 

  closed contact) must be connected to the converter and 

 evaluated.
•  Check that the mains voltage matches the ratings on 

 the nameplate.
•  The safety earth terminal can be found in the terminal box.

Note!

For operation of the drive motor with a frequency 

converter, the following points should also be 

noted:
• Motors may only be operated on a frequency 

converter if they have “/FU” (which denotes 

“frequency converter compatible”) marked on 

the nameplate, or if they have been ordered as 

“frequency converter compatible” motors and 

con

fi

 rmed.

• The frequency converter supply voltage must 

only be a maximum of 400 V without the motor 

fi

 lter.  Appropriate measures, such as a motor 

fi

 lter to protect the motor, must be installed on 

the motor terminals with longer cables, higher 

frequency converter supply voltages and/or if 

the pulse voltages are exceeded (max. 1000 Vpk 

for drive motors up to 0.75 kW, maximum 1300 

Vpk for drive motors larger than 0.75 kW). Please 

contact the converter supplier in this case. If a 

motor 

fi

 lter is included in the delivery, this must 

be installed between the converter and the motor. 

Please ensure that there is suf

fi

 cient space in the 

switch cabinet and take into account the installa-

tion and assembly requirements in the operating 

instructions of the frequency converter/motor 

fi

 lter manufacturer.

• The wire running between the motor and the 

Summary of Contents for 1SD 510

Page 1: ...Assembly Instructions EN Elektror Suflant cu canale laterale Manual cu instruc iuni de exploatare i montare RO SD 20 M SE 20 SD 22 M SE 22 SD 24 M SE 24 SD 2n M SE 2n SD 4n SE 4n SD 42 SE 42 1SD 510 S...

Page 2: ...oli de Substan ele solide con inute de mediul de transport sau impurit ile trebuie s fie filtrate nainte de intrarea n suflanta cu canale laterale Nu este admis utilizare pentru medii agresive abraziv...

Page 3: ...i n vecin tatea suflantei cu canale laterale Nu este permis ca izola ia la zgomot de orice tip s conduc la o cre tere neadmis a temperaturii mediului peste max 40 C la motorul de ac ionare 1 10 Ac io...

Page 4: ...au oc Valori admise de oscila ie a suflantei cu canele laterale Vezi ISO 14694 BV 3 Suflant cu canale laterale cu picior n uruba i fix la locul de utilizare pe o baz plan rigid i cu o capacitate porta...

Page 5: ...id cu sensul indicat de s ge ile de pe carcasa amorti zorului de zgomot n cazul unui sens incorect trebuie schim bate ntre ele L1 i L3 Conexiunea stea triunghi Motoarele de putere peste 3 0 kW sunt pr...

Page 6: ...uni a suflantei cu canale laterale este important ca transformatorul convertizo rul de frecven s ndeplineasc urm toarele cerin e Puterea convertizorului egal sau mai mare dec t puterea motorului Curen...

Page 7: ...esponsabilul cu exploatarea trebuie s stabileasc n nume propriu intervalele de cur are inspec ie i ntre inere Inspec ie i ntre inere imediat C nd survin vibra ii i oscila ii debit de aer sc zut Indica...

Page 8: ...IUNE I DEMONTARE Separarea tuturor conexiunilor electrice i a altor m suri electrotehnice n leg tur cu scoaterea din func iune este permis a fi efectuat numai de c tre un electrician specialist autori...

Page 9: ...arte intele de protec ie ale Directivei tensiunilor joase 2014 35 UE Conform Anexei I nr 1 5 1 a Directivei de ma ini Punerea n func iune a cvasima inii este interzis at ta vreme p n c nd este stabili...

Page 10: ...for the standard version is 20 C to 40 C Solid particles or con taminants must be removed by a filter unit before entering the side channel blower The ambient temperature must not exceed 40 C or unde...

Page 11: ...ped as stand ard with V belt pulleys for narrow V belts accord ing to DIN 7753 To avoid premature damage to the deep groove ball bearings the V belt drives must be correctly pretensioned The V belt dr...

Page 12: ...ons Cover open intakes or outlets with protective grating according to DIN EN ISO 13857 The belt drive and rotating parts must be covered with a belt guard according to DIN EN ISO 13857 Ensure adequat...

Page 13: ...gned to be installed in other machines or systems by qualified per sonnel i e not intended for consumers The manufacturer of the final system machine must guarantee confirm that the final system machi...

Page 14: ...or application manuals provided by the frequency converter supplier to guarantee a safe and trouble free operation It is also important to note that special ambient conditions may lead to a high level...

Page 15: ...on approx every 5 000 operating hours New V belts must be checked after a running in time of 2 hours and re tensioned if neces sary For data relevant to the V belt drive of your unit please refer to t...

Page 16: ...fil the protective regulations of the Low Voltage Directive 2014 35 EC according to Annex I No 1 5 1 of the Machinery Directive The commissioning of the partially completed machine is not permitted un...

Page 17: ...17 Operating and assembly instructions SD www elektror com 024118 07 16 06 EN...

Page 18: ...024118 07 16 06 9 DESEN EXPLODAT BROKEN VIEW DRAWING 14 31 49 32 37 43 42 41 47 46 45 44 35 20 19 18 17 16 15 40 39 38 36 35 34 33 29 30 29 28 26 25 18 48 24 23 22 21 27 20 13 12 10 9 8 7 6 5 4 3 2 1...

Page 19: ...tec ie Protective grating 12 Material spongios Foam 13 Flan Flange 14 urub Screw 15 Etan are arbori radiali Radial shaft seal 16 aib distan ier Spacer 17 Buc Bush RO EN Pos Denumire Designation 34 uru...

Page 20: ...6202 60 1 05 120 1 05 110 0 29 200 277 346 480 5 1 15 1 25 0 67 0 71 3345 8 5 65 71 SE 20 50 0 95 80 0 95 75 0 19 230 1 60 2800 10 450 8 5 62 70 6202 6202 60 1 15 120 1 15 110 0 33 230 2 35 3400 10 4...

Page 21: ...0 3 5 200 1 60 207 253 360 440 7 5 4 3 2870 23 64 60 4 25 210 4 25 220 2 20 220 250 415 480 8 0 4 6 3450 23 70 50 3 5 270 3 5 220 2 20 207 253 360 440 8 1 4 6 2840 25 64 60 4 25 290 4 25 260 3 80 220...

Page 22: ...5 370 8 5 300 6 1 440 520 10 3 10 2 3500 64 81 84 60 IE3 8 5 260 8 5 300 4 8 480 7 60 3525 64 81 84 SD 80 50 8 9 330 8 9 280 5 5 360 440 11 0 9 6 2890 76 77 81 6308 6306 60 10 5 300 10 5 300 6 8 440...

Page 23: ...8 90 5 30 5 20 3535 35 73 79 60 IE3 4 2 340 4 2 300 2 64 277 480 7 60 4 40 3480 35 73 79 SD 600 50 4 3 300 4 3 270 2 6 207 253 360 440 9 70 9 20 5 60 5 30 2825 35 73 84 6306 6206 60 5 2 300 5 2 280 3...

Page 24: ...A SD 22 FU FUK 80 1 1 80 2 2 270 2 2 230 1 1 400 3 4 4400 17 73 85 6204 6202 80 2 2 270 2 2 230 1 1 400 3 4 4400 13 73 85 SD 4n FU FUK 80 4 0 80 4 0 370 4 0 340 4 0 400 7 8 4670 37 80 82 6204 6205 80...

Page 25: ...orelui Type Volumetric fl ow rate Total pressure difference Maximum permitted blower speed Power demand at maximum permitted speed V belt drive profi le according to DIN 7753 Number of grooves Weight...

Page 26: ...26 024118 07 16 06...

Page 27: ...27 024118 07 16 06...

Page 28: ...t la www elektror com V st la dispozi ie cu pl cere departamentul nostru de asisten clien i Customer Support la num rul de telefonul 49 0 711 31973 111 You will find further information about our prod...

Reviews: