Point of Use

Ionizing Blower

Model 6422e/6422e-AC

User’s Manual

Summary of Contents for Ion Systems 6422e

Page 1: ...Point of Use Ionizing Blower Model 6422e 6422e AC User s Manual ...

Page 2: ...s ION Systems improves its customers business results by providing a total solution to their electrostatic discharge and electromagnetic interference challenges ION Systems is a wholly owned subsidiary of Illinois Toolworks and is located in Alameda California For more information about ION Systems visit www ion com or call 800 367 2452 ION Systems is ISO 9001 and ANSI ESD S20 20 certified 2010 IO...

Page 3: ...4 1 4 Power Requirements 5 2 Setup Operation 7 2 1 Box Contents 8 2 2 Blower Placement 9 2 3 Power Connections 12 2 4 FMS Connection 15 2 5 Turning on the Blower 17 2 6 Alarms 18 3 Maintenance 19 20 3 2 Cleaning the Chassis 21 3 3 Cleaning the Emitter Points 22 3 4 Auto Clean System 23 4 Specifications 25 5 Warranty Service 27 ...

Page 4: ...19 6422 M 01 Rev 1 1 1 Description 1 1 Point of Use Ionizing Blower 1 2 About IsoStat Technology 1 3 Performance 1 4 Power Requirements ...

Page 5: ...ate field induced charging Steady state DC ion emission provides fast discharge with low airflow allowing less disturbance of delicate product The Model 6422e has a red alarm indicator LED on the front of the chassis The eight pin terminal strip on the back of the unit provides a 4 20 mA current loop and relay output connection to your facility monitoring system FMS in addition to the 24 VDC input...

Page 6: ...e with low airflow for less disturbance of delicate product Ionizers incorporating IsoStat technology never need calibration and require very little maintenance IsoStat is based on a law of physics Conservation of Charge which states that charge cannot be created or destroyed in an isolated system By isolating the ionizer s emitter points from ground IsoStat ensures equal numbers of positive and n...

Page 7: ... of the Blower Ionization balance is better than 20V at 1 ft 30 48 cm Table 1 Performance Testing was performed with a charge plate monitor in accordance with ionization standard ANSI ESD STM3 1 2000 of the ESD Association Four second discharge at one foot distance is when operating Blower with AC power Discharge time at one foot when operating Blower with DC power is five seconds Distance Dischar...

Page 8: ...C 50 Hz systems Both 14 1320 and 14 1330 transformers provide the Blower with appropriate 24 VAC AC DC universal power supply p n 14 1322 for use with 120 240 VAC 50 60 Hz provides the Blower with 24 VDC power Caution The use of improper input voltage may result in poor perfor mance or damage to the unit Damage caused to the power supply from operation in an environment that exceeds the specified ...

Page 9: ......

Page 10: ...19 6422 M 01 Rev 1 7 2 Setup Operation 2 1 Box Contents 2 2 Blower Placement 2 3 Power Connections 2 4 FMS Connection 2 5 Turning on the Blower 2 6 Alarms ...

Page 11: ... 14 1322 If you ordered an AC DC universal power supply 14 1322 you will have one of the following plug adapters US wall outlet adapter p n 18 0285 UK wall outlet adapter p n 18 0286 Europe wall outlet adapter p n 18 0287 Australia China wall outlet adapter p n 18 0288 Figure 3 Mounting Screws and 8 pin Terminal Block ...

Page 12: ... not use this Blower in an explosive environment Poorly maintainedionizerscouldproduceelectricarcsattheemitter points and lead to detonation in an explosive environment Verwenden Sie dieses Gebläse nicht in explosionsge fährdetenBereichen SchlechtgewarteteIonisatorenkönnen an den Emitter Punkten Lichtbögen erzeugen und in explo siver Umgebung eine Explosion auslösen ...

Page 13: ...Figure 5 U bracket Holes for Mounting Figure 6 U bracket Side T knob for Tilt Adjustment ...

Page 14: ...an 12mm to attach brackets to the threaded inserts in the sides of the Blower Verwenden Sie zum Anschrauben von Halterungen an den seitlich am Gebläse Blower befindlichen Gewindeeinsätzen keine Schrauben die länger als 12mm sind ...

Page 15: ...Power Supply Connection 1 4 Power Requirements AC DC Adapter Connection Figure 6 U bracket Side T knob for Tilt Adjustment Figure 7 Push the Adapter into the AC DC Power Supply ...

Page 16: ...he unit 24 VDC 10 400 mA DC maximum and polarity Use a small flatblade screwdriver to secure cables stripped 1 4 in 6 3 mm into the terminal block See Figure 8 Flatblade Screwdriver Securing Connecting Cables Table 2 Model 6422e DC Power on Pins 7 8 Figure 8 Flatblade Screwdriver Securing Connecting Cables Pins State 24 VDC return 7 24V 6 1 Not used on Model 6422 ...

Page 17: ...oper wiring connec tions or failure to heed maximum voltage limits will not be covered by the warranty Schäden am Produkt infolge unsachgemäßer Verdrahtung oder wegen unterlassener Beachtung von maximal zuläs sigen Spannungen werden nicht durch die Garantie abgedeckt ...

Page 18: ... s Pin Description 24VDCprocessequipment power 8 24 VDC return Ground 7 24V 6 Do not use 4 20 mA current loop 5 Current loop Ground 4 Current loop 3 Open for active alarm Relay connections 2 Relay common 1 Closed for active alarm ...

Page 19: ...Table 4 FMS Output States Normal State Alarm State No Power 4 5 Current Loop 4 mA OK 20 mA Alarm 0 mA brownout ...

Page 20: ...2 5 Turning on the Blower ...

Page 21: ...2 6 Alarms Caution Achtung Blower Nicht autorisierter Service führt zum Erlöschen der Garantie und kann zu zusätzlichen Reparaturkosten führen ...

Page 22: ...3 Maintenance 3 3 Cleaning the Emitter Points 3 4 Auto Clean System ...

Page 23: ...Recommended Cleaning Materials Cleanroom compatible cleaning cloths polyester cloth is recommended Cleanroom compatible swabs Cleaning solution of 50 IPA electronic grade isopropanol 50 de ionized water ...

Page 24: ...19 6422 M 01 Rev 1 21 Moisten a cloth with the IPA solution Wipe off any dirt that may have accumulated on the unit ...

Page 25: ...ts contact ION Systems Technical Support techsupport ion com for information Ziehen Sie vor der Durchführung von Wartungsarbeiten an Emitter Punkten den Netzstecker aus dem Ionisator Lassen Sie die Hochspannungs Stromversorgung eine Minute entladen ...

Page 26: ...Auto Clean System Figure 11 Auto Clean System ...

Page 27: ...The automatic Emitter Point Cleaner can not be temporarily or permanently removed or de activated it is an integral part of the blower ...

Page 28: ...ax Output Voltage Ion Emission Emitter Points Tungsten wire internally shielded Discharge 1000 100V 4 sec 1 foot with either 24 VAC or 24 VDC Airflow Ozone Indicators Green power on LED red alarm LED Connectors Operating Temp 10 35 C 50 95 F Humidity Mounting Dimensions Weight Certifications ...

Page 29: ...ions Weight Certifications 14 1330 Transformer Input Voltage Output Characteristics Temperature Operating Humidity Short Circuit Protection Dimensions Weight Certifications 14 1322 AC DC Adapter Input Voltage Output Characteristics Temperature Operating Humidity Short Circuit pProtection Dimensions Weight Certifications ...

Page 30: ...5 Warranty Service ...

Page 31: ......

Page 32: ...Notes ...

Page 33: ...Notes ...

Page 34: ...oad Alameda CA USA 94502 Tel 510 217 0600 Fax 510 217 0484 Toll free 800 367 2452 Sales services 510 217 0460 Tech support 510 217 0470 info ion com salesservices ion com techsupport ion com service ion com www ion com ...