background image

AUTO−RUN mode: 

In AUTO-RUN mode, the NJ174 goes through all the

built-in programs in turn. To select AUTO−RUN Press the

MODE button repeatedly until

AUTO

 is shown on the

display. 

In AUTO-RUN mode the LED chase speed, flash

frequency, running speed and retention time can be set

as above. The time between program changes can also

be set. Press SETUP repeatedly until the first character

of the display shows

n

. Then use the UP and DOWN

buttons to select the time between program changes.

The run speed, fade time and flash frequency can be

adjusted as shown above.

SOUND mode:

To select SOUND mode, press MODE repeatedly until

SU

is shown in the first two characters of the display. In

SOUND mode, only the sensitivity can be set.

Press SETUP to change the sensitivity.

SU

 will be shown in the first two characters of the

display, and the sensitivity will be shown in the last two

characters of the display. Press UP or DOWN to adjust

the sensitivity.

SLAVE mode.

To select SLAVE mode, press MODE repeatedly until

SLAu

 is shown in the display.

In slave mode, the NJ174 will copy the colours and

movements of any other unit to which it connected by a

DMX cable. Connect a DMX lead from

DMXout

 of the

Master luminaire to

DMXin

 on the slave. If there is more

than one slave connect a DMX lead from

DMXout

 on

 Page 5

Summary of Contents for NJ174 COTO CIRC

Page 1: ...NJ174 OCTO CIRC 360 10mm LEDs in 3 colours Low power consumption Stand alone or DMX operation Page 1 ...

Page 2: ...hanging bracket provided To conform with Health Safety legislation a safety chain will also be required Attach the safety chain to the Safety Eye on the rear panel If permanently installed the luminaire must be installed by a competent electrician in accordance with the latest IEE Wiring Regulations Either plug the lead into a 13 A socket or remove the 13 A plug fitted and wire directly to a fused...

Page 3: ...or rug Do not allow the cable to hang over the edge of a table Arrange the cable so that it cannot cause a trip hazard This symbol means that the luminaire should mounted at least 0 3 m from any object that it is illuminating 0 3m GENERAL SAFETY REQUIREMENTS Domestic wiring must be tested periodically by a qualified electrician at least once every 10 years or at every change of occupancy For offic...

Page 4: ...d FS flash frequency SP run speed Fd fade time Each of these parameters can be changed by pressing the UP and DOWN buttons In programs 21 and 22 the background and foreground colours can be set Press the MODE button for 1 second to select which function is to be adjusted 1 sets the background colour 1 r is red 1 b is blue 1 9 is green 1 r9 is yellow 1 rb is magenta 1 b9 is cyan 1 FF is off and 1 F...

Page 5: ...shown above SOUND mode To select SOUND mode press MODE repeatedly until SU is shown in the first two characters of the display In SOUND mode only the sensitivity can be set Press SETUP to change the sensitivity SU will be shown in the first two characters of the display and the sensitivity will be shown in the last two characters of the display Press UP or DOWN to adjust the sensitivity SLAVE mode...

Page 6: ...f the first DMX control channel The 2nd DMX channel is at the DMX start address 1 the 3rd DMX channel is at the DMX start address 2 etc DMX mode The NJ174 may be controlled from DMX in 6 different modes 2 channel mode uses two channels to control the luminaire the first channel selects the program and the second channel selects the speed In 3 channel mode the luminaire is entirely illuminated in t...

Page 7: ... the brightness of the green LEDs The fourth channel sets the brightness of the blue LEDs The fifth channel selects the program The sixth channel sets the speed The seventh channel sets the flash time In 14 channel mode the luminaire is controlled in four segments The 1st 2nd and 3rd channels control the first segment red green and blue LEDs The 4th 5th and 6th channels control the second segment ...

Page 8: ... blue LEDs The 13th 14th and 15th channels control the fifth segment red green and blue LEDs The 16th 17th and 18th channels control the sixth segment red green and blue LEDs The 19th 20th and 21st channels control the seventh segment red green and blue LEDs The 22nd 23rd and 24th channels control the eighth segment red green and blue LEDs The 25th channel sets the flash rate The 26th channel is t...

Page 9: ...24 Program 18 225 233 Program 19 234 242 Program 20 243 251 Program 21 252 255 Program 22 To select DMX mode press the MODE button repeatedly until d is shown in the first character of the display Then press the UP and DOWN buttons until the required DMX start address is shown The DMX START ADDRESS is the DMX address of the first DMX control channel The 2nd DMX channel is at the DMX start address ...

Page 10: ...fety tested yearly by a qualified electrician PAT Tested in order to comply with the Electricity at Work Regulations If hired out it must be PAT tested prior to each hire We recommend that it is PAT tested regularly when used in a domestic environment DISPOSAL AND RECYCLING You must not dispose of this appliance with domestic household waste Most local authorities have specific collection system f...

Page 11: ...560 560 230 mm Weight 6 4 kg Power supply 230 V Power consumption 45 W Operating current 0 2 A Light source 360 10 mm LED Colours 3 Beam Angle 30 Mains input IEC socket DMX Connections 3 pin XLR Data pin 3 Data pin 2 Ground pin 1 Page 11 ...

Page 12: ...de to service or modify the luminaire then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations This warranty is in addition to and does not affect your statutory rights If you have any problems with this product please call our Help Desk on 0845 459 4816 The help desk is open from 8 am until 1 pm Monday to Friday Electrovision Ltd Lancots Lane Su...

Reviews: