14

14

U.S. Patent No. 11,027,991 and other U.S. and Foreign Patents Pending

ElectroStrainer Canister Installation

Canister Reassembly

 

1. 

Insert the basket into the Canister. Align the flat edge of the basket with 
the flat edge of the Canister. 

2. 

Confirm the gasket is in the top of the Canister.

3. 

The Canister and lid are keyed and can be inserted in only one direction. 
Align the flat edge of the Cell screen and strainer basket. Make sure 
the lid key is aligned with the Canister. Then insert the Cell Assembly         
into the Canister. 

 

 

           

DO NOT use chemicals, acids, descaling 

solutions or zincs in the ElectroStrainer Canister or on the Cell. 
This will damage the Cell.

 

4. 

Add the pressure ring to the top of the Canister. Bleed excess air from 
the Canister, then tighten down the wing nuts evenly. Do not use tools 
to perform this tightening process. Work in a star pattern so all are 
evenly secure. 

5. 

Double check all fittings, hose clamps and wing nuts are secure.
Open the seacock valves and verify there are no leaks.

WARNING

Gasket

 

Flat Edge

 

2

1

Lid Key

 

3

4

Summary of Contents for ElectroStrainer ES-100

Page 1: ...888 384 8881 952 475 8084 support electrosea com www electrosea com InstallationManual Models ES 125 ES 100 ElectroStrainer System...

Page 2: ...s any liability assumed for damages resulting from the use of this product and information contained herein 1 Table of Contents Introduction Table of Contents 1 ElectroSea and ElectroStrainer System 2...

Page 3: ...in a sea strainer and completely redefines seawater system maintenance ElectroStrainer is a Biofouling Prevention Device ElectroStrainer continuously creates a safe and effective level of chlorine to...

Page 4: ...Flow Sensor 20 6 1m 4 Mounting Screws 10 x 1 2 54cm 1 Canister Strainer Basket and Cell 1 ClearVis Flow Sensor 4 Hose Connectors 1 Top Side Mounting Bracket 1 Bottom Side Mounting Bracket 2 Machine Sc...

Page 5: ...ion descaling ensures any existing biofouling that has accumulated on the interior seawater lines are removed If seawater lines are impacted with barnacles and marine growth then ElectroSea recommends...

Page 6: ...ill continue generating chlorine even after a Strainer Flow Alert occurs If a Strainer Flow Alert occurs 1 Check vessel intake screens for blockage or debris 2 Check seawater pump output impeller or o...

Page 7: ...hwater run off Low salinity is the most frequent cause of the CELL Indicator ElectroStrainer will not display CLEANING or generate chlorine while vessel is operating in freshwater RESOLUTION Vessel re...

Page 8: ...ft 6 1m 20 ft 6 1m 1 Electrical Connection Overview DO NOT cut extend or splice the Cell cable DO NOT connect multiple Cell cables together The Cell Extended Cables in the table below show the total c...

Page 9: ...stainless and other high quality materials Use of non factory or substitute parts will void the Warranty Seawater Connection Overview 1 Locate the vessel s seawater intake pump strainer if existing a...

Page 10: ...Unsecure the pressure ring by turning the wing nuts counterclockwise 3 Remove the Cell Assembly Lift straight up by the black plastic cover Do not lift or pull on the cable Set the Cell Assembly aside...

Page 11: ...WARNING OPTION B Side Mounting 1 Mount Level 1 Mount Canister to flat interior engine room surface 2 Insert 3 12 mounting screws into base tab to secure the Canister 3 Donotscrewthroughhullofboat WAR...

Page 12: ...ecommended that thread sealant without PTFE is used The ClearVis Flow Sensor measures the velocity of seawater using speed of sound technology It is preferable to have 12 30 5cm of straight hose befor...

Page 13: ...w Sensor is on the output of the ElectroStrainer Canister with at least 12 of straight hose after the Flow Sensor All seawater flowing through the ElectroStrainer Canister Assembly must flow through t...

Page 14: ...Clamp The Strain Relief Clamp can be connected to the feet if using the base mount or bottom wall bracket as shown U S Patent No 11 027 991 and other U S and Foreign Patents Pending ElectroStrainer C...

Page 15: ...sket Make sure the lid key is aligned with the Canister Then insert the Cell Assembly into the Canister DO NOT use chemicals acids descaling solutions or zincs in the ElectroStrainer Canister or on th...

Page 16: ...on the vessel Connect the RED and YELLOW wires of the Power Cable to this source according to the appropriate electrical standards i e ABYC Connect the Power Cable A to the Control Unit Control Unit t...

Page 17: ...4 lbs 6 oz 1 98 kg 4 lbs 6 oz 1 98 kg Power Source 12 or 24 VDC 12 or 24 VDC Power Consumption Max power 50 watts Typical power 20 watts Max power 50 watts Typical power 20 watts Internal circuit brea...

Page 18: ...l end user purchaser of a Product directly from ElectroSea or an authorized ElectroSea Dealer a Direct Purchaser or 2 The original end user purchaser of a new vessel in which a new Product was install...

Page 19: ...er the type and length of vessel on which the Product is used and a reasonably complete description of the problem you are having ElectroSea may require that you send the Product to ElectroSea at your...

Page 20: ...750074 007 888 384 8881 952 475 8084 support electrosea com www electrosea com...

Reviews: