ElectroStrainer Canister Installation
Canister Reassembly
1.
Insert the basket into the Canister. Align the flat edge of the basket with
the flat edge of the Canister.
2.
Confirm the gasket is in the top of the Canister.
3.
The Canister and lid are keyed and can be inserted in only one direction.
Align the flat edge of the Cell screen and strainer basket. Make sure
the lid key is aligned with the Canister. Then insert the Cell Assembly
into the Canister.
DO NOT use chemicals, acids, descaling
solutions or zincs in the ElectroStrainer Canister or on the Cell.
This will damage the Cell.
4.
Add the pressure ring to the top of the Canister. Bleed excess air from
the Canister, then tighten down the wing nuts evenly. Do not use tools
to perform this tightening process. Work in a star pattern so all are
evenly secure.
5.
Double check all fittings, hose clamps and wing nuts are secure.
Open the seacock valves and verify there are no leaks.
WARNING
Gasket
Flat Edge
2
1
Lid Key
3
4