Connect the aircraft static line (airspeed) line to the port on the PT-30Alt. Be sure this line is tight. The
port is a 1/4" flare union. Care should be taken not to put excess pressure on the flexible line.
Make sure
the flexible line does not kink.
G. Other Pressure Transducer Installations:
Other pressure transducers (Hydraulic Pressure, Cabin Pressure, Cabin Altitude Pressure, etc.) have the
same form factor as the Gyro Vacuum Transducer or the Oil Pressure Transducer and should be mounted
in the aircraft in the same manner as appropriate.
Note: Any or - pressure inputs on the EDC
must be tied to a ground pin on the 37-pin connector.
2.7 Install the Interface Circuit for Annunciators:
Any Temperature or Resistive Fuel Level channel on the EDC may be used to monitor the state of a switch, relay or
output from a device. This output can be used to trigger a light (annunciator) on the MVP. Annunciator lights such
as Chip Detect, Bypass, De-ice, Pitot Heat, Fire, Fault, Exceedance, etc. can be displayed on the Main or System
screen on the MVP. To monitor a voltage, various VI-221 (Voltage Interface Units) will be required, depending on the
configuration.
B. Switch to Ground with Load Referenced to Bus
EDC
Temp or Resistive Fuel
Level Channel
EDC
Pressure Channel
Bus
VI-221
VI-221-P
Light, Horn, etc.
Switch or Relay
Load
OR
EDC
Temp or Resistive Fuel
Level Channel
EDC
Pressure Channel
Bus
Bus
VI-221-PU
VI-221P-PU
Switch or Relay
OR
A. Switch To Ground without a Load present
14
Summary of Contents for MVP-50T
Page 2: ...ii ...
Page 12: ...xii ...
Page 14: ...2 ...
Page 20: ...8 ...
Page 34: ...22 ...
Page 36: ...24 ...
Page 42: ...30 ...
Page 44: ...32 ...
Page 48: ...36 ...
Page 50: ...38 ...
Page 54: ...42 ...
Page 61: ...Template for MVP Cutout 49 ...
Page 62: ...Template for EDC 50 ...
Page 64: ...52 ...
Page 72: ...60 ...
Page 74: ...62 ...
Page 86: ...STC AML 74 ...
Page 87: ...75 ...
Page 88: ...76 ...
Page 90: ...78 ...