6. Configure the MVP to Receive the Second EDC Input:
Power up the MVP and use the buttons to navigate to the "Engine Data, Ports, Timers, etc. Setup" screen from the
"System Configuration Screens Menu." Scroll down to the line that reads "Port3 RS232 Input/Output/Baud:" and
select "EDC#2/OFF/19200." Your MVP must be running software with an ID of 2.x.x or greater to use the second
EDC.
7. Input Ambient Temp Calibration Data for the Second EDC:
Navigate to the "5. EDC Input Cal." screen found in the System Configuration Screens Menu. Change the "Input" line
to "Temp Comp 2." Scroll to the "Reset values back to factory defaults" line found at the bottom of the screen and
select "Yes." Next, Scroll to "Offset" and set its value to the value written on the middle connector that came with the
second EDC. You're Done.
83