LOCKOUTS
Lockout 2 now must be linked to the other
presets to unlock the 10-Button station. To
setup Lockout 2 to the other stations:
Select preset 2 in room 1:
Press Preset.
Press Up button to select preset 1.
Select Lockout 1:
Press Lockout.
Use Up/Down buttons to select lockout
action 2.
Repeat the same action for presets 3
through 13 (OFF is 13). Now all presets except
preset 1 will lock the station. Remember once
the station is locked out, it is inoperable and
must be unlocked by another station.
33
+Min
+10
-10
-Min
Rm 1
Pr 2
Name PR2
Lockout 2
+Min
+10
-10
-Min
Rm 1
Pr 2
Name PR2
Lockout 1
EXAMPLE: A ONE PRESET
LOCK
For this example, the SMART System will
lock and unlock the same 10-Button station
in a single room. The system will be setup
such that presets located on the left hand
side of the controls (presets 1, 2, 3, 7, 8, 9,
and OFF) will lock the 10-Button, and
presets on the right hand side (presets 4, 5,
6, 10, 11, and 12 ) will unlock. In this
example, the 10-Button station will be on
address 0.
TO SETUP:
Lockouts
Timers
Password
Config
Clear Sys
Stations
Dim Patch
Combines
From Preset Menu,
To Setup a Lockout Action to
lock the 10-Button,
Press Menu.
Press Lockouts.