Datalog Enable:
Allows the use of on board data logging function. Options are RPM to begin data logging
and Frequency (5, 10, 20 Hz) sampling rate. Wires the same as any input that is switched, such as the Valet
Rev Limiter.
Voltage Input:
No options, it just gives you a recordable voltage from 0 – 5 volts.
Timed Ignition Cut:
option for shifting requires minimum RPM and minimum MAP value, amount of
time for ignition cut in milliseconds, amount of time before ignition can be cut again. Finally, there is an
option to pull to 12v (activate high) or pull to 0v (activate low). Additionally, the line must be released
before the channel can be activated again.
H.1.b. Wiring the GPI’s
Fig H.1.1:
Potentiometer wiring for Fuel,
Ignition and GP I/O Trim Inputs
Fig. H.1.2:
Air conditioner
idle speed
increase wiring.
Fig. H.1.3:
Alternate air
conditioner idle speed
increase wiring. Note
that the A/C clutch
solenoid polarity
MUST be known for
this method.
______________________________________________________________________________________
TECgt Manual Version 2.0
- Page 99 -