Technical Support - DMM
72/80
599 74 98-60 Rev.00
Make a note of the latch and hook with which it is secured to the tub.
If the hook securing the chamber to the welded tub is broken.
Use the eyelet (indicated by the red arrow).
Use a screw Code 405 50 33-52/8 (AF/2P 5x16 TE/SP must have a
maximum length of 16 mm and without a tip to avoid perforating the tub),
secure the chamber to the tub as shown by the arrow in the photo.
When repositioning the pressure chamber in the tub drain pipe, pay
attention to the references.
The size of the clamp to use is 52.5 mm.
When reassembling the pressure chamber, reposition the pipe connecting the pressure switch so that it never actually
touches the cabinet.
Filter
body
Remove the worktop.
Remove the control panel.
Remove the iron ring securing the bellow seal to the front panel.
Unfasten the screws securing the door safety interlock.
Remove the front panel.
Loosen the screws securing it to the front crossbar (1).
Pull out the main drain pipes (2) and circulation pump connection pipe.
Raise it to remove the support inserted in the side crossbar (3).
Remove the pump protection.
Drain
pump
Release the connectors.
Move the lock catch with some pliers (take care not to break it).
Turn and pull out the pump.
If the lock catch securing the pump to the filter body breaks.
Secure the pump to the filter body, securing it in place using a screw, screwing
the latter in the slot shown by the arrow.
Size of the screw 3.5x19 Code 5024 79 51- 00/2.
2
1
1
2
2
3