10.18 Flowmeter
10.18.1 General characteristics
1. Main
circuit
board
2. Flow
meter
A built-in flow meter, which measures the quantity of water in litres that is loaded into the appliance.
In the event of a sensor failure, the water level is controlled by the water level sensor.
Electronically controlled valve,
exploded view
PCB Turbine
1-PCB
4-Diffuser
2-Turbine
5-Double
filter
3-Deflector
6-Reed switch
7-Magnet
Flowmeter