12 ACCESSIBILITY
12.1 Worktop
Remove the screws that secure it to the back panel.
Pull it out from the back.
12.2 From the worktop, you can access
1. Main board
2. Solenoid valves
3. Control panel
4. Display board/light diffuser/buttons/buttons springs assembly
5. Electronic water level sensor
6. Detergent container
7. Detergent fill pipe
8. Upper counterweight
12.2.1 Main
board
Remove the worktop.
Unfasten the three screws securing it to the cabinet.
Move it in the direction of the dotted arrow.
Place the wiring behind the hook securing the board to the back panel.
Remove the wiring from the side hook of the board protection.
1
2
3
4
5
6
7
8