Technical Support - DMM
66/80
599 74 98-60 Rev.00
To reassemble the door safety interlock, repeat the same tasks in reverse order.
Before tightening the screws to secure the door safety interlock to the front
panel, make sure the flange is positioned properly on the outside as
indicated by the arrows.
Tighten the screws at a torque of 2.5 Nm.
12.3.3 Drum
light
Remove the iron ring securing the bellow seal to the unit.
Remove the part of the bellow seal concerned from the unit.
Remove the wiring from the lamp holder.
Take out the hook securing it to the bellow seal.
Take the lamp out of its seat.
12.3.4 Bellow
seal
Remove the iron ring securing the bellow seal to the unit.
Release the bellows seal from the front panel.
Take the drum light out of its seat.
Take the seal out of the welded tub
(take care as the seal is held in position by a snap ring).
When reassembling the seal.
Lubricate with liquid soap the part where the tub is inserted.
Make sure the references are aligned.
Reassemble the snap ring between the door bellow seal and the tub.
Reassemble the iron ring between the door bellow seal and the cabinet.