Technical Support - DMM
70/80
599 74 98-60 Rev.00
12.4 From the front panel, you can access
1. The front counterweight
2. The shock absorbers
3. The drain water circuit
4. The pressure chamber
5. The tub suspension springs
6. The shock absorber pins
12.4.1 Front
counterweight
Remove the worktop.
Remove the control panel.
Remove the iron ring securing the bellow seal to the front panel.
Unfasten the screws securing the door safety interlock.
Remove the front panel.
Pull out the Jet pipe.
Pull out the lamp from its seat.
Unfasten the five screws securing the front counterweight to the welded tub
assembly.
When tightening the screws, take care:
If the welded tub assembly is new, tighten the screws at a torque of 15 Nm.
If the welded tub assembly is not new, align with the existing thread and
tighten the screws at a torque of 10÷12 Nm.
12.4.2 Shock
absorber
Remove the worktop.
Remove the control panel.
Remove the iron ring securing the bellow seal to the front panel.
Unfasten the screws securing the door safety interlock.
Remove the front panel.
Pull out the pins securing it to the tub and crosspiece.