- Verify that all internal hoses do not leak.
- Inspect the drive belt. Adjust the tension or replace if necessary.
- Check that water does not leak onto the floor.
- If the heating time is unusually long, check the heating elements. If
the water is very hard, check whether there are lime deposits on the
heating elements. Decalcify the elements if necessary. Adapt the
amount of deliming agent to the manufacturer’s guidelines.
- Never switch on the heating elements when there is no water in the
machine. This will cause the slow-blow fuse to trigger.
- Inspect the shock absorbers and coil springs. (Only EX- and
H-model).
Preventive maintenance
Summary of Contents for W4105N
Page 2: ......
Page 6: ...6 ...
Page 12: ......
Page 44: ......
Page 70: ......
Page 84: ...84 22F x I O modules ...
Page 85: ...85 6637 22G The gas heating unit must be connected to connections 17 18 and 19 I O modules ...
Page 88: ......