90
6659
7
6
14
K21
M1
9
1
10
11
12
13
2
E1 – E3
8
2
3
4
5
Door and door lock
Function
The door lock locks the door
When the door is closed (closed door lock switch S3), the programme unit
may request door locking by applying a voltage of 200-240 V on the door
lock controller A31 input X92.
The following check is made by the A31 card prior to locking of the door:
•
No water in drum
- input "level" from level guard B2 is closed = 0 V
•
Drum not turning
- pulse frequency on input "Tacho" from rotation
sensor B3 less than 0.4 Hz.
When the above conditions are met, the card A1 outputs a closing pulse
on output D0 to the door lock actuator/coil, which then locks the door. The
micro switches S4a and S4b in the actuator/door lock are closed when the
door is locked. These micro switches feed voltage to:
•
The output relays
on the programme unit card. The relays control the
machine’s drain and water valves as well as heater switch-on.
•
Interlock signal
for motor control (input X302) that releases the motor
start prevention state.
Programme operation is now possible.
2
1. Program unit A1
2. Temperature sensor B1
3, Level switch B2
4, Level switch B4
5. Display A2
6. Heater element E1 -3
7. Motor control U1
8. Rotation sensor B3
9. Door lock module A41
10. Voltage unit A5
11. I/O board
12. Watervalves
13. Drain valve
14. Power supply PSU
Summary of Contents for W4105N
Page 2: ......
Page 6: ...6 ...
Page 12: ......
Page 44: ......
Page 70: ......
Page 84: ...84 22F x I O modules ...
Page 85: ...85 6637 22G The gas heating unit must be connected to connections 17 18 and 19 I O modules ...
Page 88: ......
Page 94: ......
Page 110: ......
Page 118: ......
Page 121: ......
Page 122: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...