26
Troubleshooting
Fault code 04, NTC LOW TEMP
This fault code is generated by the programming CPU card. This fault code
is displayed if the temperature around the NTC sensor is below approx. -9
degrees C.
A low temperature means the resistance in the sensor is too high, above
approx. 23.7 kohm. This can be because the machine has been standing
outdoors, an open circuit in the sensor, a break in the cable to the sensor,
etc.
The resistance should be as shown in the table below:
Approximate values of a fault free temperature sensor
T (°C)
R (ohm)
19
6100
20
5850
21
5600
22
5350
23
5100
Fault code 05, NTC HIGH TEMP
This fault code is generated by the programming CPU card. This fault code
is displayed if the temperature around the NTC sensor e98 de-
grees C.
A high temperature means the resistance in the sensor is too low, lower
than approx. 350 ohm. This can be caused by a short circuit in the sensor,
break in the cable to the sensor, etc.
Fault code 06, WATER IN MACHINE
This fault code is generated by the programming CPU board. This fault
code may appear only in the case of rapid advance to the end of the
program. The fault code will appear if the level system has not indicated
“empty drum” within a certain time (approx. 3 min). This time may vary
depending on the size of the machine.
Action:
• Check drain for dirt.
• Blow through the level hose and check that it is not blocked and does
not contain any water.
• Check in the service program that the level control is working correctly.
• Adding too much detergent
Summary of Contents for W4105N
Page 2: ......
Page 6: ...6 ...
Page 12: ......
Page 44: ......
Page 70: ......
Page 84: ...84 22F x I O modules ...
Page 85: ...85 6637 22G The gas heating unit must be connected to connections 17 18 and 19 I O modules ...
Page 88: ......
Page 94: ......
Page 110: ......
Page 118: ......
Page 121: ......
Page 122: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...