119
Preventive maintenance
To maintain correct and proper functioning and to prevent interruption of
service, the following maintenance scheme should be adhered to.
The maintenance interval should be adapted to how frequently the machi-
ne is used.
Daily
• Check the door and door lock:
- Let the door remain open and try starting the machine. The machine
should not start.
- Close the door, start the machine and try opening the door. It should
not be possible to open the door until the drum has stopped turning.
- Check that the door does not leak.
- Clean the door seal, removing any detergent and fluff.
• Check that the drain valve does not leak during the wash cycle.
• Clean out any detergent remaining in the detergent compartment. Rapid
advance through a program and let the water rinse the compartment:
Every third month
May only be carried out by authorized personnel.
• Check that the door does not leak.
• Check the drain valve and remove any fluff.
• Inspect the interior of the machine (during an actual wash cycle to en
-
sure that no leaks are noticed) by:
- Turning of the main power switch of the machine.
- Remove the top cover and the protective front and rear plates.
Preventive maintenance
Summary of Contents for W4105N
Page 2: ......
Page 6: ...6 ...
Page 12: ......
Page 44: ......
Page 70: ......
Page 84: ...84 22F x I O modules ...
Page 85: ...85 6637 22G The gas heating unit must be connected to connections 17 18 and 19 I O modules ...
Page 88: ......
Page 94: ......
Page 110: ......
Page 118: ......
Page 121: ......
Page 122: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...