20
Installation
5917
13
5918
14
5919
15
5920
16
5921
17
5922
18
13
14
15
16
17
18
Installation on an excisting floor or foundation
Instead of braking up the excisting floor or foun-
dation, chemical bolts M16 can be used.
Mounting instruction
• Drill ø 18 mm (11/16") to a depth of 125 mm
(5"). Do not make the hole too deep.
• Clean the drilled holes.
• Put down the chemical ampule in the hole.
• Rotate the bolt into the hole, so that the glass
ampule is broken and its contents mixed.
• Rotate the bolt to correct depth.
NOTE!
Do not rotate the bolt against the con-
crete bottom. Check that the chemicals have
filled the hole completely.
• Remove the drilling machine with the moun
-
ting tool. Hold the bolt with one hand. Let the
bolt harden before the machine is mounted.
Time for hardening, due to different concrete
temperatures.
– 10°C
6 hours
– 5°C
2.5 hours
± 0°C
1 hour
5°C
30 minutes
10°C
20 minutes
15°C
15 minutes
20°C
10 minutes