Installation - electric, steam and gas heating
487 18 39 01 - 300/500/750 - GB
28
Technical data, type 300/30
Heating
Electric
Steam
Gas
Drum volume:
286 litres
286 litres
286 litres
Weight:
Net
220 kg
220 kg
220 kg
485 lb
485 lb
485 lb
Drum:
Diameter
680 mm
680 mm
680 mm
Depth
790 mm
790 mm
790 mm
Revolutions per minute
44 rpm
44 rpm
44 rpm
G-factor
0.8
0.8
0.8
Capacity:
13.6 kg
13.6 kg
13.6 kg
30 lb
30 lb
30 lb
Motor:
Effect without reverse
0.37 kW
0.37 kW
Effect with reverse
2 x 0.37 kW
2 x 0.37 kW
Revolutions per minute 50 Hz
1400 rpm
1400 rpm
Revolutions per minute 60 Hz
1680 rpm
1680 rpm
Effect of drum motor
0.37 kW
Effect of fan motor
0.37 kW
Drum motor- revolutions 50 Hz
1400 rpm
Drum motor- revolutions 60 Hz
1680 rpm
Fan motor - revolutions 50 Hz
1400 rpm
Fan motor - revolutions 60 Hz
1680 rpm
Heat effect:
Electric heating
13.5 kW
Electric heating
18.0 kW
Gas heating
21.0 kW
Air consumption:Electric
13.5 kW
430 m
3
/h
Electric
18.0 kW
690 m
3
/h
Steam
925 m
3
/h
Gas
690 m
3
/h
Pipe connection: Evacuation
Ø 200
Ø 200
Ø 200
Steam:
ISO 7/1-Rp1/2
Condensate outlet:
ISO 7/1-Rp1/2
Steam:
Recommended pressure (absolute)
100-1000 kPa
Max. allowable pressure
1000 kPa
Drop in pressure:Evacuation
Gas pipe connection:
ISO 7/1-R1/2
Gas pressure:
See page regarding pressure
Noise level:
< 70 dB (A)
< 70 dB (A)
< 70 dB (A)
Variable, depen-
dent upon
steam pressure
max.
80 Pa
max.
20 Pa
max.
80 Pa
Summary of Contents for TT300
Page 1: ...Operating and installation manual TT300 TT500 TT750 487 1839 51 01 99 31 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Instructions for use 18 487 18 39 01 300 500 750 GB ...
Page 26: ...General installation 487 18 39 01 300 500 750 GB 26 ...
Page 38: ...Installation electric steam and gas heating 487 18 39 01 300 500 750 GB 38 ...
Page 46: ...Installation electric steam and gas heating 487 18 39 01 300 500 750 GB 44 2 ...