Installation - electric, steam and gas heating
487 18 39 01 - 300/500/750 - GB
36
Only one
cable
for heat-
ing and
motor
Electric heating
, fuse sizes, effects and voltages
400V
*
3NAC 50/60 Hz
31.3 kW
50A
400-440V 3AC 50/60 Hz
31.3 kW
50A
400V
*
3NAC 50/60 Hz
37.3 kW
63A
400-440V
3AC 50/60 Hz
37.3 kW
63A
230-240V
3AC 50/60 Hz
31.3 kW
100A
230-240V
3AC 50/60 Hz
37.3 kW
100A
Voltage
Total
output
Fuse
Within the EU and EEA - type 750/75/650
Only one
cable
for con-
trol and
motor
Steam and gas heating
, fuse sizes, effects and voltages
400V
*
3NAC 50/60 Hz
2.0 kW
10A
400-440V
3AC 50/60 Hz
2.0 kW
10A
230-240V
3AC 50/60 Hz
2.0 kW
10A
230-240V
1AC 50/60 Hz
2.0 kW
10A
Voltage
Total
output
Fuse
Electric installation
Electric
Steam
Gas
*
If the machine is equipped with a zero voltage connection, this must always be connected