SOI/DT 2010-03 dmm
62/78
599 72 84-41
Alarm
Description
Possible fault
Machine status/action
Reset
E62
Overheating during washing
(temperature higher than 88°C for
more than 5 min.)
Wiring faulty; NTC sensor for wash cycle faulty; Heating element
faulty; Main PCB faulty.
Safety drain cycle
Cycle stops with door open
RESET
E66
Heating element power relay faulty
(incongruence between sensing and
relay status)
Main PCB faulty;
Safety drain cycle
Cycle stops with door open
RESET
E68
Earth-leakage (value of grid voltage
different from main value)
Earth-leakage between heating element and earth
Cycle stops with door open
RESET
E69
Heating element interrupted
Wiring faulty; Heating element for washing interrupted (thermal fuse
open)
---------------- START/RESET
E71
NTC sensor for wash cycle faulty
(short-circuited or open)
Wiring faulty; NTC sensor for wash cycle faulty;
Main circuit board faulty.
Heating phase is skipped
START/RESET
E72
Fault in NTC sensor on drying
condenser (voltage out of range,
short-circuit or open circuit)
Wiring faulty; Drying NTC sensor (condenser) improperly positioned
or faulty; Main WD PCB faulty.
The heating phase
is skipped
START/RESET
E73
Fault in NTC sensor on drying duct
(voltage out of range, short-circuit or
open circuit)
Wiring faulty; Drying NTC sensor (duct) improperly positioned or
faulty; Main WD PCB faulty.
The heating phase
is skipped
START/RESET
E74
NTC sensor for wash cycle
improperly positioned
Wiring faulty; NTC sensor for wash cycle improperly positioned; NTC
Sensor faulty; Main PCB faulty.
Heating phase is skipped
START/RESET
E82
Error in selector reset position
Main PCB faulty (Incorrect configuration data).
---------------- RESET
E83
Error in reading selector
Main PCB faulty (Incorrect configuration data).
Cycle cancelled
START/RESET
E91
Communication error between main
PCB and display
Wiring faulty; Control/display PCB faulty
Main circuit board faulty.
---------------- RESET
E92
Communication incongruence
between main PCB and display
(incompatible versions)
Incorrect control/display PCB;
Incorrect PCB (do not correspond to the model).
Cycle blocked
ON/OFF
E93
Appliance configuration error
Main PCB faulty (Incorrect configuration data);
Cycle blocked
ON/OFF
E94
Incorrect configuration of washing
cycle
Main PCB faulty (Incorrect configuration data);
Cycle blocked
ON/OFF
E95
Communication error between
micro-processor and EEPROM
Main circuit board faulty.
Cycle blocked
RESET
E97
Incongruence between programme
selector and cycle configuration
Main PCB faulty (Incorrect configuration data).
Cycle blocked
RESET
E98
Communication error between main
PCB – Inverter
Incompatibility between main PCB and Inverter
Cycle blocked
ON/OFF
E9b/E9H
Communication error between
micro-processor and FLASH
memory
Display board
----------------
ON/OFF
RESET
E9C
Appliance configuration error
Display board
----------------
ON/OFF
RESET