![Electrolux ProClean RealLife EDW1xxx-2G Series Service Manual Download Page 33](http://html.mh-extra.com/html/electrolux/proclean-reallife-edw1xxx-2g-series/proclean-reallife-edw1xxx-2g-series_service-manual_2382017033.webp)
SOE/PR
33
599 72 48-93
9.2.11.3 “iC2” code
-
The washing programme is suspended but it can be restarted if the alarm conditions no longer apply.
9.2.11.4 “iC3” code – Communication between the mother board and the motor control board
-
The alarm is signalled if the communication between the mother board and the motor control board
does not start.
-
Acoustic signal and visual alarm, depending on the appliance customisation; the washing
programme is restarted automatically if the error conditions no longer apply.
9.2.12 “iD0” code family: Tacho problems
9.2.12.1 “iD0” code – no signal
-
The alarm is stored and displayed only in service mode; there is a new control for each new phase.
-
If the washing pump is activated but there is no tacho signal for 30 sec then the motor speed is set to
full speed and the heating element is not activated.
9.2.12.2 “iD1” code
-
The alarm is stored and displayed only in service mode.
-
If the washing pump is activated but there is no tacho signal for 5 sec then the heating element is
temporarily deactivated. If after another 30 sec there is still no signal the appliance displays an error
code iD0.
9.2.13 “iE0” code family: Flowmeter position
-
The alarm is stored and displayed only in service mode; there is a new control for each new phase.
-
The alarm is signalled if the desired position of the flowmeter is not reached after 120 sec; the
heating element is deactivated.
-
If the signal from the flowmeter does not change after 15 sec, the software suspends the positioning
for 2 sec and resumes after another max 120 sec.
9.2.14 “iF0” code family: Over-filling
9.2.14.1 “iF0” code
-
The alarm is stored and displayed only in service mode; the programme continues.
-
The error situation is recognised when the total filling times exceed the limits.
-
The times are accumulated at each subsequent filling and reset every time the drain is activated.
-
If the alarm is detected, the heating element is not activated and the subsequent fillings are ignored.
9.2.14.2 “iF1” code
-
The alarm is stored and displayed only in service mode.
-
The alarm condition is recognised if the safety water level is exceeded for more than 4 sec.
-
A drain phase is activated until the water level drops below the safety level.
-
The washing programme continues only if this condition is achieved.
Summary of Contents for ProClean RealLife EDW1xxx-2G Series
Page 6: ...SOE PR 6 599 72 48 93 3 2 Fully Integrated EDW1953 EDW1103 ...
Page 7: ...SOE PR 7 599 72 48 93 3 3 Built In ...
Page 8: ...SOE PR 8 599 72 48 93 EDW750 EDW1850 EDW1950 EDW3510 EDW2500 SWISS ...
Page 9: ...SOE PR 9 599 72 48 93 EDW 500 EDW 503 EDW 1503 ...
Page 14: ...SOE PR 14 599 72 48 93 6 2 3 EDW750 6 2 4 EDW1850 1950 6 2 5 EDW1953 TOUCH ...
Page 25: ...SOE PR 25 599 72 48 93 7 13 EDW750 7 14 EDW1850 1950 7 15 EDW1953 TOUCH ...
Page 54: ...SOE PR 54 599 72 48 93 10 14 EDW1xxx 2G operating diagram ...
Page 55: ...SOE PR 55 599 72 48 93 10 15 EDW3000 operating diagram single phase motor ...
Page 56: ...SOE PR 56 599 72 48 93 10 16 EDW3000 operating diagram three phase Inverter motor ...