![Electrolux ProClean RealLife EDW1xxx-2G Series Service Manual Download Page 16](http://html.mh-extra.com/html/electrolux/proclean-reallife-edw1xxx-2g-series/proclean-reallife-edw1xxx-2g-series_service-manual_2382017016.webp)
SOE/PR
16
599 72 48-93
7 Service
Mode
Settings
Only if the appliance is on stand-by awaiting instructions, hold down the two configured buttons
simultaneously, turn on the appliance and wait for at least 4 sec.
With EDW1xxx-2G display boards: by pressing buttons S1+S3.
With EDW3xxx display boards: by pressing buttons S1+S3 (EDW2500) or S3+S4 (EDW2503).
7.1 EDW500
7.1.1 Diagnostics mode, alarm reading and testing
1. Hold down button
S1
2. Turn the knob anti-clockwise to
Position 5
ª
LEDs LD0 and LD1 flash
ª
release
button
S1
3. Press
button
S1
ª
the first alarm stored is displayed: the
Cycle end
LED
flashes in sequence, interrupted by pauses, corresponding
to the alarm: for the alarm code, please see the alarms
summary table.
4. Press
button
S1
again to display the second alarm
5. Press
button
S1
once more to display the third alarm
6. Press
button
S1
for the fourth time to move on to enabling the appliance's actuators, the CYCLE END
LED is on:
ª
4th activation: regenerating solenoid valve
ª
5th activation: drain pump
ª
6th activation: water fill to level solenoid valve
ª
7th activation: heating (only if the level of water is reached)
ª
8th activation: washing pump
ª
9th activation: detergent/rinse aid dispenser
ª
10th activation: drying fan (if turbo-dry)
7. All the positions can be repeated by pressing button S1 in sequence
The components are powered if the appliance door is shut: open the door to select another
actuator then shut it again.
If button S1 is not pressed for 60 seconds, you automatically quit diagnostics mode.
Summary of Contents for ProClean RealLife EDW1xxx-2G Series
Page 6: ...SOE PR 6 599 72 48 93 3 2 Fully Integrated EDW1953 EDW1103 ...
Page 7: ...SOE PR 7 599 72 48 93 3 3 Built In ...
Page 8: ...SOE PR 8 599 72 48 93 EDW750 EDW1850 EDW1950 EDW3510 EDW2500 SWISS ...
Page 9: ...SOE PR 9 599 72 48 93 EDW 500 EDW 503 EDW 1503 ...
Page 14: ...SOE PR 14 599 72 48 93 6 2 3 EDW750 6 2 4 EDW1850 1950 6 2 5 EDW1953 TOUCH ...
Page 25: ...SOE PR 25 599 72 48 93 7 13 EDW750 7 14 EDW1850 1950 7 15 EDW1953 TOUCH ...
Page 54: ...SOE PR 54 599 72 48 93 10 14 EDW1xxx 2G operating diagram ...
Page 55: ...SOE PR 55 599 72 48 93 10 15 EDW3000 operating diagram single phase motor ...
Page 56: ...SOE PR 56 599 72 48 93 10 16 EDW3000 operating diagram three phase Inverter motor ...