![Electrolux ProClean RealLife EDW1xxx-2G Series Service Manual Download Page 30](http://html.mh-extra.com/html/electrolux/proclean-reallife-edw1xxx-2g-series/proclean-reallife-edw1xxx-2g-series_service-manual_2382017030.webp)
SOE/PR
30
599 72 48-93
9.2
Description of the alarms
9.2.1 “i00” code family: Low mains voltage
The electronic board makes sure the dishwasher operates within certain voltage limits. If - during a cycle -
the voltage drops below the lowest limit, the electronic board suspends all loads and interrupts the cycle
under way. The “i00” alarm is then triggered. The lowest main voltage threshold is 180 Volt.
If the voltage goes back to over 186 Volt, the electronic board cancels the error status and the cycle
resumes. The “i00” alarm is also deleted.
If the mains voltage continues to exceed the maximum threshold, the electronic board does not do anything.
IMPORTANT: the “i00” alarm is not stored and cannot therefore be read in Service Mode.
9.2.2 “i10” code family: Water tap closed
9.2.2.1 “i10" code – during static filling
This alarm code is used to display problems with the water inlet tap closed at the beginning of the
programme. It is set up to detect problems during the static water filling. A drain phase is performed before
the error is displayed to the user.
-
Acoustic signal and visual alarm, depending on the appliance customisation; the programme can be
restarted.
-
The water level defined is not reached within the time limit set.
-
The time limit set starts when the fill solenoid valve is opened.
-
The time limit set is reset when the fill solenoid valve is closed.
-
The water will first be drained before an error is displayed to the user.
-
Time limit set: Normal 90 sec; Test cycle = 30 sec (times could differ as they are defined in the
washing cycle specifications).
9.2.2.2 “i11" code – during dynamic filling
-
Acoustic signal and visual alarm, depending on the appliance customisation; the programme can be
restarted.
-
The water level defined is not reached within the time limit set.
-
The time limit set starts when the fill solenoid valve is opened.
-
The time limit set is reset when the fill solenoid valve is closed.
-
The water will first be drained before an error is displayed to the user.
-
Time limit set: Normal 120 sec; Test cycle = 60 sec (times could differ as they are defined in the
washing cycle specifications).
9.2.3 “i20”
code
family: Draining problems
-
Acoustic signal and visual alarm, depending on the appliance customisation; the programme can be
restarted.
-
The level switch restore point is not reached within the time limit set.
-
The time limit set starts when the drain pump is activated.
-
The time limit set is reset when the drain pump stops normally.
-
Time limit set: Normal 90 sec; Test cycle = 60 sec.
9.2.4 “i30” code family: Aqua Control
9.2.4.1 “i30”
code
-
Acoustic signal and visual alarm, depending on the appliance customisation; the programme is
restarted automatically in this alarm condition.
-
If this alarm condition occurs, the drain pump is activated.
-
Time limit set: 10 sec.
Summary of Contents for ProClean RealLife EDW1xxx-2G Series
Page 6: ...SOE PR 6 599 72 48 93 3 2 Fully Integrated EDW1953 EDW1103 ...
Page 7: ...SOE PR 7 599 72 48 93 3 3 Built In ...
Page 8: ...SOE PR 8 599 72 48 93 EDW750 EDW1850 EDW1950 EDW3510 EDW2500 SWISS ...
Page 9: ...SOE PR 9 599 72 48 93 EDW 500 EDW 503 EDW 1503 ...
Page 14: ...SOE PR 14 599 72 48 93 6 2 3 EDW750 6 2 4 EDW1850 1950 6 2 5 EDW1953 TOUCH ...
Page 25: ...SOE PR 25 599 72 48 93 7 13 EDW750 7 14 EDW1850 1950 7 15 EDW1953 TOUCH ...
Page 54: ...SOE PR 54 599 72 48 93 10 14 EDW1xxx 2G operating diagram ...
Page 55: ...SOE PR 55 599 72 48 93 10 15 EDW3000 operating diagram single phase motor ...
Page 56: ...SOE PR 56 599 72 48 93 10 16 EDW3000 operating diagram three phase Inverter motor ...