20
$IWHUFRQ¿UPLQJWKHDERYHFRQGLWLRQV
prepare the wiring as follows:
The screws which fasten the wiring to
the terminal block may come loose from
vibrations during transportation.
Check and make sure all screws are well
¿[HG2WKHUZLVHLWFRXOGFDXVHEXUQRXW
of the wires.
%HVXUHWKHFLUFXLWFDSDFLW\LVVXI¿FLHQW
Ensure the starting voltage is maintained
at over 90% of the rated voltage marked
on the nameplate.
&RQ¿UPWKDWWKHFDEOHWKLFNQHVVLV
DVVSHFL¿HGLQWKHSRZHUVRXUFH
VSHFL¿FDWLRQ
Always install a Residual Current Device
(RCD) in wet or moist area.
The following may be caused by voltage
drop: Vibration of a contactor, which will
damage the contact point, fuse blowing,
disturbance of the normal function of the
overload.
The means for disconnection from a
power supply shall be incorporated in the
¿[HGZLULQJDQGKDYHDQDLUJDSFRQWDFW
separation of at least 3mm in each active
(phase) conductor.
Downward
slope
B. Check the drainage
Carefully pour a glass of water on the
evaporator.
(QVXUHWKHZDWHUÀRZVWKURXJKWKHGUDLQ
hose of the indoor unit without any leakage
DQGJRHVRXWWKHGUDLQH[LW
Drain hose
C. Dain piping
The drain hose should
point downward for
HDV\GUDLQÀRZ
Step 10: Checking the Drainage
A. Open and lift the indoor unit front panel.
Hold the lower part of the left and right sides
of the panel, pull it against you and lift it stops
with a full support from the bracket.
Do not place drain piping as indicated below:
Panel
bracket
caution
Accumulated
drain water
Do not rise
Tip of drain
hose dipped
in water
Air
Space less
than 50mm
Water
leakage
Water
leakage
Water
leakage
Ditch