13
Turn lightly the cable to make the
connection easier later.
Be careful not to let the drain hose
become slack.
Heat insulate the connecting pipe.
Be sure that the drain hose is located at
the lowest side of the buddle. Locating
at the upper side can cause drain pan to
Never cross connect or interwind the
power wire with any other wiring.
outdoor unit.
Do not plug the cable to the indoor unit.
That must be done later.
Do not allow the piping to be exposed
out from the back of the indoor unit.
If part of the drain hose is positioned
inside the room, wrap it with insulating
materials so as to prevent condensed
water from dropping.
Fixing lower hook
4 Take out the piping from body case, wrap
the piping, power cords, drain hose with the
tape and then make them pass through the
piping hose.
Do not put any object in the drain pan
located in the rear of the indoor unit, as the
condensed water is gathered there and
piped out of the room.
5 Hang the mounting slots of the indoor unit on
the upper hooks of the mounting plate and
To ease the piping installation, put a spacer
between the indoor unit and the wall.
Indoor Unit
Piping
insulation
Upper hook
Mounting
plate
Spacer
Liquid pipe
Gas pipe
Connecting
cable
6 Press the lower left and right sides of the unit
against the mounting plate until the lower
hooks engage into their slots.
Drain hose
Drain hose
Mounting plate
7 The installation site should be 2.3 meters or
caution
Upper hook
Connecting
cable