SOI/DT 2007-11 dmm
54/69
599 70 39-88
Alarm
Possible fault
Action/machine status
Reset
E51
PCB faulty; current leakage from motor or from wiring.
Cycle blocked, door locked (after 5
attempts).
RESET
E52
Motor faulty; wiring faulty; PCB faulty.
Cycle blocked, door locked (after 5
attempts).
RESET
E53
PCB faulty.
Cycle blocked, door locked.
RESET
E54
PCB faulty; current leakage from motor or from wiring.
Cycle blocked, door locked (after 5
attempts).
RESET
E57
Wiring defective on inverter for motor, inverter board defective.
Cycle stops with door locked (after 5
attempts).
RESET
E58
Wiring defective on inverter for motor, inverter board defective, abnormal motor
operation (motor overloaded);
Motor defective.
Cycle stops with door locked (after 5
attempts).
RESET
E59
Motor defective; Wiring defective on inverter for motor;
Inverter board defective.
Cycle stops with door locked (after 5
attempts).
RESET
E5A
Inverter board defective. NTC open (on the inverter board).
Overheating caused by continuous operation or ambient conditions (let appliance
cool down).
Cycle stops with door locked (after 5
attempts).
RESET
E5H
Wiring defective, Inverter board defective.
Cycle stops with door locked (after 5
attempts).
RESET
E5C
Inverter board defective, the masters voltage is too high (measure the masters
voltage).
Cycle stops with door locked (after 5
attempts).
RESET
E5d
Line interference, Wiring defective, defective main board or inverter board.
Cycle stops with door locked (after 5
attempts).
RESET
E5E
Defective wiring between main board and inverter board, Defective inverter board,
defective main board.
Cycle stops
ON/OFF
E5F
Defective inverter board, Defective wiring, defective main board.
Cycle stops with door locked (after 5
attempts).
RESET
E61
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
The heating phase is skipped.
START/RESET
E62
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped
with door open.
RESET
E66
PCB faulty.
Safety drain cycle – Cycle stopped
with door open.
RESET
E68
Earth-leakage between heater and earth.
Cycle blocked with door open.
RESET
E69
Washing heating element interrupted (thermofuse open)
----------------
START/RESET
E71
Faulty NTC sensor; Wiring faulty;
PCB faulty.
Heating is skipped.
START/RESET
E72
Wiring faulty; Drying NTC sensor (condenser) faulty; PCB faulty.
Drying heating is skipped
START/RESET
E73
Wiring faulty; Drying NTC sensor (duct) faulty; PCB faulty.
Drying heating is skipped
START/RESET
E74
NTC sensor improperly positioned; Faulty NTC sensor; Wiring faulty; PCB faulty.
Heating is skipped.
START/RESET