SOI/DT 2007-11 dmm
55/69
599 70 39-88
Alarm
Possible fault
Action/machine status
Reset
E82
PCB faulty (Wrong configuration data). Selector, wiring
----------------
RESET
E83
PCB faulty (Wrong configuration data). Selector, wiring
Cycle cancelled.
START/RESET
E91
Wiring faulty; Faulty control/display board
PCB faulty.
----------------
RESET
E92
Wrong control/display board;
Wrong PCB (do not correspond to the model).
Cycle interrupted.
OFF/ON START
E93
Incorrect configuration data; PCB faulty.
Cycle interrupted.
OFF/ON
E94
Incorrect configuration data; PCB faulty.
Cycle interrupted.
OFF/ON
E95
PCB faulty.
Cycle interrupted.
RESET
E97
Faulty PCB (Wrong configuration data).
Cycle interrupted.
RESET
E98
Incompatibility between main board and Inverter.
Cycle interrupted.
OFF/ON
E9b / E9H
Display board.
Cycle interrupted.
ON/OFF RESET
E9C
Display board.
Cycle interrupted.
ON/OFF RESET
E9d
Display board.
Cycle interrupted.
ON/OFF RESET
E9F
PCB.
Cycle interrupted.
OFF/ON
EH1
Power supply problems (incorrect / disturbance); PCB faulty.
Wait for frequency nominal
conditions.
OFF/ON
EH2
Power supply problems (incorrect / disturbance); PCB faulty.
Wait for voltage nominal conditions.
OFF/ON
EH3
Power supply problems (incorrect / disturbance); PCB faulty.
Wait for voltage nominal conditions.
OFF/ON
EHE
Wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped
with door open.
RESET
EHF
PCB faulty.
Safety drain cycle – Cycle stopped
with door open.
RESET
EC1
Solenoid valve faulty/blocked; PCB faulty.
Cycle interrupted with door closed.
Drain pump functions always (5 min.,
then it stops for 5 min. etc.)
RESET
EC3
Wiring faulty; Weight sensor faulty; PCB faulty.
----------------
START/RESET
Ed1
Wiring faulty between PCB and WD board; WD board faulty; PCB faulty.
Cycle interrupted.
OFF/ON
Ed2
Wiring faulty between PCB and WD thermostats; WD board faulty; PCB faulty.
Cycle interrupted with door open.
RESET
Ed3
Wiring faulty between PCB and WD thermostats; WD board faulty; PCB faulty.
Cycle interrupted with door open.
RESET
Ed4
Wiring faulty: WD board faulty; PCB faulty.
Cycle interrupted with door open.
RESET
EF1
Drain tube blocked/kinked/too high;
Drain filter dirty/blocked.
Warning displayed at the end of cycle
(specific LED).
START/RESET
EF2
Excessive detergent dosing; drain tube kinked/blocked;
Drain filter dirty/blocked.
Warning displayed after 5 attempts or
by the specific LED.
RESET
EF3
Water leaks onto base frame; water control system defective.
Machine drains and cycle stops
ON/OFF RESET
EF4
Tap closed, water pressure too low.
---------------------------
RESET