13
www.electrolux.com
Final vacuum is
poor
The set vacuum
percentage is incorrect.
The cover gasket is dirty
or worn.
The cover is not closed
correctly.
Change the vacuum percentage.
Clean or replace the cover
gasket (contact the Technical
Assistance Service for a
replacement).
Close the cover correctly.
Make sure that objects or dirt are
not found between the cover and
tank.
The cover does
not open
No power supply.
Wait until the power supply is
restored.
If the machine does not work properly after the above-mentioned checks, contact the
assistance service describing the detected defect.
Alarm messages
The appliance detects some alarms,
which are displayed -
11
-.with the
following messages:
OIL:
Replace the pump oil.
Contact the technical assistance
service.
OFF:
The electronic board is blocked.
Contact the technical assistance
service.
EAA:
The appliance has not reached the
vacuum within the maximum set time
(160 seconds).
Make sure the cover is closed
correctly.
The cover has not been closed during
the P7 program “Conditioning
Program”.
Switch the appliance off and on to
reset the alarm.
FLA:
Power supply voltage is low.
Contact the technical assistance
service.
12.
ENVIRONMENT CONCERNS
Recycle the materials with this
symbol. Put the packaging in applicable
containers to recycle it.
Help protect the environment and human
health and to recycle waste of electrical
and electronic appliances.
Do not dispose appliances marked
with this symbol with the household
waste. Return the product to your local
recycling facility or contact your
municipal office.