Page
17 DW 107
COMPONENT TESTING
In order to facilitate testing of the components, a Test Procedure has been created showing the contacts
to which the probes of the tester should be connected and the reading for each component.
To gain access to the electronic control board and the harness connectors, dismantle the door.
•
Remove the harness connectors from the control board, connect the probes of the tester to the points
indicated in the table and compare the actual reading with the theoretical value.
•
If preferred components that are easily accessible can be tested directly on the component. (Wiring
connections are excluded)
COMPONENTS
CONTACTS
CORRECT VALUE
NOTES
POWER CABLE &
* L - C4*
0
Ω
ON/OFF SWITCH
* N - A1
0
Ω
With ON/OFF key pressed
INTEGRATED DISPENSER
C1 - C2
1500
Ω
± 8%
OK
HEATING ELEMENT
(+ SAFETY THERMOSTAT)
C3 - A2
25
Ω
± 8%
Connected in series
(2100 W)
DOOR MICROSWITCH
C3 - C4
0
Ω
With door CLOSED
TACHYMETRIC SENSOR
C5 - C6
135
Ω
± 8%
OK
INFINITY
With Rinse-Aid
RINSE-AID SENSOR
D1 - D2
0
Ω
Without Rinse-Aid
I
NFINITY
With Salt
SALT SENSOR
E4 - E5
0
Ω
Without Salt
6.030
Ω
± 8%
(at 20 ºC)
TEMPERATURE SENSOR
E2 - E3
1.010
Ω
± 8%
(at 65 ºC)
700
Ω
± 8%
(if the RESET solenoid is
interrupted)
RESET SOLENOID
E1 - D3
610
Ω
± 8%
OK
DRAIN MOTOR
E1 - F1
70
Ω
± 8%
OK
WASHING MOTOR
E1 - F3
50
Ω
± 8%
OK
REGENERATION SOLENOID
E1 - F4
5.100
Ω
± 8%
OK
FILL SOLENOID
(+ ANTI-FLOODING device)
E1 - F5
3.800
Ω
± 8%
Connected in series
INFINITY
EMPTY position (1-2)
PRESSURE SWITCH
E1 – F7
0
Ω
FULL position (1-3)
NOTE: - *Measurement points L - N refer to the pins on the plug on the service cord.
REGENERATION CYCLE
The level of regeneration can be selected electronically with
10
regeneration levels.
«DISPLAY»
WASHING CYCLE
FILL
PHASE
HARDNESS OF WATER
LEVEL
AUTONOMY
REGEN.
N
°
PPM (Parts per million)
[
L
.
0
]
No regeneration
-
0 – 80
[
L
.
1
]
8 cycles
at 9th cycle
40
81 – 140
[
L
.
2
]
6 cycles
at 7th cycle
30
141 – 200
[
L
.
3
]
4 cycles
at 5th cycle
20
201 – 300
*
[
L
.
4
]
3 cycles
at 4th cycle
15
301 – 400
[
L
.
5
]
2 cycles
at 3rd cycle
10
401 – 500
[
L
.
6
]
1 cycle
at 2nd cycle
5
501 – 600
[
L
.
7
]
601 – 700
[
L
.
8
]
701 – 800
[
L
.
9
]
0 cycles
Every cycle
1
801 – 900
* L
.
4 Standard factory setting
Summary of Contents for ESI6180U
Page 2: ...Page 2 DW 107 MODELS ESI6180X EX VIEW DRAWING 3927 ESI6180U OUTER PANEL LINER ASSEMBLY ...
Page 4: ...Page 4 DW 107 MODELS ESI6180X EX VIEW DRAWING 3926 ESI6180U ELECTRICAL ASSEMBLY ...
Page 6: ...Page 6 DW 107 MODELS ESI6180X EX VIEW DRAWING 3890 ESI6180U WATER CIRCUIT ASSEMBLY ...
Page 8: ...Page 8 DW 107 MODELS ESI6180X EX VIEW DRAWING 3924 ESI6180U WATER SOFTENER ASSEMBLY ...
Page 10: ...Page 10 DW 107 MODELS ESI6180X EX VIEW DRAWING 3928 ESI6180U DOOR PANEL ASSEMBLY ...
Page 12: ...Page 12 DW 107 MODELS ESI6180X EX VIEW DRAWING 3925 ESI6180U BASKET ASSEMBLY ...